Design and function
Transport and installation
30
099-000109-EW501
23.08.2018
5.1.5.1 Approved coolants overview
Coolant
Temperature range
KF 23E (Standard)
-10 °C up to +40 °C (14 °F up to +104 °F)
KF 37E
-20 °C up to +30 °C (-4 °F up to +86 °F)
5.1.5.2 Maximal hose package length
All information relates to the total hose package length of the complete welding system and presents
exemplary configurations (of components of the EWM product portfolio with standard lengths). A straight
kink-free installation is to be ensured, taking into account the max. delivery height.
Pump: Pmax = 3,5 bar (0.35 MPa)
---------------------------------------------------------------------------------------------------------------------
►
Power source
Hose package
Wire feeder
miniDrive
Welding torch
Max.
Compact
(25 m / 82 ft.)
(5 m / 16 ft.)
30 m
98 ft.
(20 m / 65 ft.)
(5 m / 16 ft.)
Decompact
(25 m / 82 ft.)
(5 m / 16 ft.)
(15 m / 49 ft.)
(10 m / 32 ft.)
(5 m / 16 ft.)
Pump: Pmax = 4.5 bar (0.45 MPa)
---------------------------------------------------------------------------------------------------------------------
►
Power source
Hose package
Wire feeder
miniDrive
Welding torch
Max.
Compact
(25 m / 82 ft.)
(5 m / 16 ft.)
30 m
98 ft.
(30 m / 98 ft.)
(5 m / 16 ft.)
40 m
131 ft.
Decompact
(40 m / 131 ft.)
(5 m / 16 ft.)
45 m
147 ft.
(40 m / 131 ft.)
(25 m / 82 ft.)
(5 m / 16 ft.)
70 m
229 ft.
5.1.5.3 Adding coolant
The unit is supplied ex works with a minimum level of coolant.
Figure 5-1
Item Symbol
Description
0
1
Coolant tank cap