Rectifying faults
Display machine control software version
82
099-000120-EW501
26.07.2011
7.4
Display machine control software version
NOTE
The query of the software versions only serves to inform the authorised service staff!
0
1
0
1
Figure 7-2
Display Setting/selection
Exit the menu
Exit
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
Software version query (example)
07=
System bus ID
02c0= Version
number
System bus ID and version number are separated by a dot.
7.5
General operating problems
7.5.1
Interface for mechanised welding
WARNING
No function of the external shut-down devices (emergency stop switch)!
If the emergency stop circuit has been realised using an external shut-down device via
the interface for mechanised welding, the device must be set for this setup. If this is not
observed, the power source will ignore the external shut-down devices and will not shut
down!
• Disconnect jumper 1 on PCB T320/1 (Tetrix) or M320/1 (Phoenix / alpha Q)!