Design and function
Advanced settings
099-000120-EW501
26.07.2011
69
5.13.3
Configuring the TIG potentiometer torch connection
DANGER
Risk of injury due to electrical voltage after switching off!
Working on an open machine can lead to fatal injuries!
Capacitors are loaded with electrical voltage during operation. Voltage remains present
for up to two minutes after the mains plug is removed.
1.
Switch off machine.
2.
Remove the mains plug.
3.
Wait for at last 2 minutes until the capacitors have discharged!
WARNING
Risk of accidents if these safety instructions are not observed!
Non-observance of these safety instructions is potentially fatal!
• Carefully read the safety information in this manual!
• Observe the accident prevention regulations in your country.
• Inform persons in the working area that they must observe the regulations!
CAUTION
Test!
Before re-commissioning, it is essential that an "inspection and test during operation"
is carried out conforming to IEC / DIN EN 60974-4 "Arc welding devices - inspection and
testing during operation"!
• For detailed instructions, please see the standard operating instructions for the welding
machine.
When connecting a potentiometer torch, jumper JP27 on PCB T320/1 inside the welding machine
should be unplugged.
Welding torch configuration
Setting
Prepared for TIG standard or up/down torch (factory setting)
:
JP27
Prepared for potentiometer torches
JP27
A
B
C
D
E
F
G
H
Poti-Brenner
10k
B2-
Uref.+10V
0V
0V
BT1
BT2
IH-Down
Up
Poti/UD ein
Figure 5-30
NOTE
For this torch type the welding machine has to be set to torch mode 3, see chapter
"Setting torch mode and Up/Down speed".