Machine description – quick overview
Machine control – Operating elements
099-000120-EW501
26.07.2011
23
Item Symbol Description
0
8
AMP%
Secondary current (TIG) / pulse pause current
Setting range 1 % to 100 % (1 % increments). Percentage of the main current.
9 sec
Down-slope time (TIG)
0.00 s to 20.0 s (0.1 s increments).
The down-slope time can be set separately for non-latched and latched.
10 AMP% End-crater
current
(TIG)
Setting range 1 % to 200 % (1 % increments). Percentage of the main current.
11
sec
Gas post-flow time (TIG)
Setting ranges: 0.00 sec to 40.0 sec (0.1 sec increments).
12
Tungsten electrode diameter / Ignition optimisation (TIG)
Infinitely adjustable from 1 mm to 4 mm or greater (0,1 mm increments)
Alternating current balance (TIG AC)
Max. setting range: -30 % to +30 % (1 % increments). The setting range may also be
lower depending on the factory setting.
Optimisation of cleaning effect and fusion penetration characteristics.
13
Balance fast TIG DC pulses
Setting range: 1 % to +99 % (1 % increments)
14
Alternating current frequency (TIG AC)
50 Hz to 200 Hz (1 Hz increments).
Constriction and stabilisation of the arc:
The cleaning effect increases with a greater frequency. Particularly thin panels (welding
with a low current), anodised sheet aluminium or highly contaminated articles for
welding can be welded and cleaned perfectly at a higher frequency.
Frequency fast TIG DC pulses
Setting range: 50 Hz to 15 kHz
15
activArc TIG welding process
• Switch activArc on or off
• Correct the activArc characteristic (setting range: 0 to 100)