Design and function
Machine configuration menu
66
099-000229-EW501
14.04.2015
Display
Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode (factory setting 1)
Up-/Down speed
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
Setting the first increment
Setting: 1 to 20 (factory setting 1)
Machine configuration
Settings for machine functions and parameter display
Welding current display (ignition, secondary, end and hotstart currents)
• Pro = welding current display as a percentage of the main current (factory setting)
• Abs = absolute welding current display
Non-latched operation (C version)
• on = on
• off = off (factory setting)
Power display switching (MMA)
• on = actual value display
• off = setpoint value display (factory setting)
Pulses in the upslope and downslope phases
The function can be switched on or off
TIG antistick
• on = function active (factory setting).
• off = function inactive.
Program 0 block
With machines with key switch (access block), program 0 can be disabled. When the
access block has been enabled, programs 1
–x only can be switched.
off
All programs can be selected (ex works)
on
Programs 1
–x can be selected (program 0 disabled)
Warnings
Warnings can be issued prior to a machine failure.
off
Warnings disabled (ex works)
on
Warnings enabled
Machine configuration (part two)
Settings for machine functions and parameter display
Ramp function Remote control RTF 1
The ramp function can be switched on and off
spotMatic
Variation of operation mode spotArc, ignition with workpiece contact
• on = on
• off = off (factory setting)
Setting spot time
• on = Short spot time (5 ms - 999 ms, 1 ms- steps)
• off = long spot time (0,01 s - 20,0 s, 10 ms- steps)