Machine description
– quick overview
Machine control
– Operating elements
18
099-000229-EW501
14.04.2015
4.3
Machine control
– Operating elements
Machine control provides the user with up to 8 welding tasks (JOBs).
JOB 0 represents manual operating mode. This is where you can change/optimise all parameters
directly in machine control - See 5.7.3.1 Manual, standard operation (JOB 0) chapter.
Figure 4-3
Item Symbol
Description
0
1
Error/status indicators
Collective interference signal light
Water deficiency signal light (welding torch cooling)
Excess temperature signal light
safety sign signal light
2
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
3
Switch display/JOB number button
AMP
Welding current display
VOLT
Welding voltage display
JOB
Display and select JOB number
4
Welding process button
MMA welding, lights up in green / arcforce setting, lights up in red
TIG welding
5
Operating mode / Power-saving mode button
spotArc / Spotmatic (spot time setting range)
Non-latched
Latched
Press for 3 s to put machine into power-saving mode. To reactivate, activate one of the
operating elements- See 5.9.7 Power-saving mode (Standby) chapter.