Design and function
Menus and sub-menus on the machine control
60
099-000124-EW501
29.07.2011
Display Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode
• Modes 1-6: with tapping function (factory setting 1)
• Modes 11-16: without tapping function
Setting the first increment
Setting: 1 to 20 (factory setting 1)
Up-/Down speed (not available in modes 4 and 14)
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
Machine configuration
Settings for machine functions and parameter display
Welding current display (ignition, secondary, end and hotstart currents)
• Pro = welding current display as a percentage of the main current (factory setting)
• Abs = absolute welding current display
Non-latched operation (C version)
• on = on
• off = off (factory setting)
Power display switching (MMA)
• on = actual value display
• off = setpoint value display (factory setting)
spotMatic
Variation of operation mode spotArc, ignition with workpiece contact
• on = on
• off = off (factory setting)
Ramp function Remote control RTF 1
The ramp function can be switched on and off
Pulses in the upslope and downslope phases
The function can be switched on or off
Torch cooling mode
• AUt = automatic operation (ex works)
• on = permanently switched on
• off = permanently switched off
Expert menu
activArc voltage measuring
• on = function on (factory setting)
• off = function off
Error output to automated welding interface, contact SYN_A
off
AC synchronisation or hot wire (factory setting)
FSn
Error signal, negative logic
FSP
Error signal, positive logic
AvC
AVC (Arc voltage control) connection
Automation menu
Fast take-over of control voltage (automation)
• on = function on
• off = function off (factory setting)
Orbital welding
• off = off (ex works)
• on = on