Design and function
Interfaces for automation
50
099-000124-EW501
29.07.2011
5.9
Interfaces for automation
CAUTION
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause
damage to the machine.
• Only use shielded control leads!
• If the machine is to be operated with control voltages connection via suitable isolation
amplifiers is required!
• To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).
5.9.1
Remote control connection socket, 19-pole
A
B
L
F
C
D
E
T
S
V
K
U
J
R
H
M
N
P
G
6
6
7
4
3
2
2
1
10
5
9
11
12
8
10-100K
10V
I>0
0-10V
I
(1V=100A)
SOLL
0-10V
0V
+15V (max. 75mA)
-15V (max. 25mA)
START / STOP
AMP / AMP%
(PULS)
10-100K
A
B
C
N
P
R
S
T
U
V
D
E
F
G
H
J
K
L
M
Figure 5-22
Pos. Pin
Signal
shape Designation
1
A
Output
Connection for cable screen (PE)
2
B/L
Output
Current flows signal I>0, galvanically isolated (max. +- 15V/100mA)
3
F
Output
Reference voltage for potentiometer 10V (max. 10mA)
4
C
Input
Control value specification for main current, 0-10V (0V = I
min
, 10V = I
max
)
5
D
Input
Control value specification for secondary current, 0-10V (0V = I
min
, 10V
= I
max
)
6 J/U Output
Reference
0V
7
K
Output
Power 15V, max. 75mA
8
V
Output
Power supply -15V, max. 25mA
9
R
Input
Start/Stop welding current
10
H
Input
Switching between main and secondary welding currents (pulses)
11 M/N/P
Input
Activation
of
control voltage specification
Set all 3 signals to reference potential 0V to activate external control
voltage specification for main and secondary currents
12 G
Output
Measured
value
I
SETPOINT