Functional characteristics
Menus and sub-menus on the machine control
48
Item No.: 099-000155-EWM01
5.8
Menus and sub-menus on the machine control
5.8.1
Direct menus (direct access to parameters)
Functions, parameters and their values can be accessed directly, e.g. can be selected by pressing a
button once.
5.8.2
Expert menu (TIG)
The expert menu includes functions and parameters which are either not set on the machine control, or
which do not require regular setting.
Figure 5-16
Display Setting/selection
Expert menu
Slope time tS1 (main current to secondary current)
Setting: 0.00 s to 20.0 s (factory setting 0.01 s)
Slope time tS2 (secondary current to main current)
Setting: 0.00 s to 20.0 s (factory setting 0.01 s)
Wire return
• Increase value = more wire return
• Reduce value = less wire return
Parameter can also be set after connecting a TIG cold wire feed unit. Setting: 0 to 255
(factory setting 50).
activArc parameter
Parameter can also be set after activating TIG activArc welding.
Display shown = factory setting.