Functional characteristics
Machine configuration menu
60
099-00T401-EW501
01.02.2022
Display
Setting/selection
Torch configuration menu
Set welding torch functions
Torch mode (ex works 1)
> see 5.1.9.2 chapter
Alternative welding start – tapping start
Available from torch mode 11 (welding stop by tapping remains active).
------- Function enabled (ex works)
------- Function disabled
Up/down speed
> see 5.1.9.3 chapter
Increase value > rapid current change
Decrease value > slow current change
Current jump
> see 5.1.9.4 chapter
Current jump setting in ampere
Get JOB number
Set maximum selectable jobs (setting: 1 to 128, factory setting 10).
Additional parameter after activating the BLOCK JOB function.
Start JOB
Set first JOB to get (setting: 129 to 256, factory setting 129).
Machine configuration
Settings for machine functions and parameter display
Absolute value setting (ignition, secondary, end and hot start cur-
rent)
> see 4.2.1 chapter
------- Welding current setting, absolute
------- Welding current setting, as a percentage of the main current (ex works)
Non-latched operation (version C)
> see 5.1.4.6 chapter
------- Function enabled
------- Function disabled (ex works)
Welding current actual value display
> see 4.2 chapter
------- Actual value display
------- Nominal value display
Pulsed TIG welding (thermal)
------- Function enabled (ex works)
------- For special applications only
MMA pulse shape
------- MMA average value pulsing (ex works)
------- MMA average value pulsing, manual
TIG average value pulsing
------- Average value pulsing enabled
------- Average value pulsing disabled (ex works)
TIG average value pulsing
------- Average value pulsing enabled
------- Average value pulsing disabled (ex works)
Pulsed TIG welding (thermic) in the upslope and downslope pha-
ses
> see 5.1.7.3 chapter
------- Function enabled (ex works)
------- Function disabled
Filler wire welding, operating mode
2
------- Filler wire operation for automated applications,
wire is fed when current flows
------- Non-latched operating mode (ex works)
------- 3rd cycle operating mode
------- Latched operating mode