Rectifying faults
Resetting the control (Reset all)
099-005207-EW501
18.05.2017
45
7.2.1
Setting the machine type
Operating
element
Action
Result
1 x
Switch off the welding machine
+
Keep both push-buttons pressed
1 x
Switch on the welding machine; the display shows “Anl”.
With “Anl” on the display, set the machine type:
0 ---------- Saturn 251 FKG
1 ---------- Saturn 301 FKG
2 ---------- Saturn 351 FKG
3 ---------- all decompact (DK, DG FDG, FDW)
7 ---------- Mira 301 FKG
After a few seconds, the selected machine type is applied and the
display switches back to the welding parameter nominal values.
7.3
Resetting the control (Reset all)
M2.xx control
The first action should always be to check and if necessary correct the machine type setting.
All user settings will be overwritten with factory settings and must therefore be checked
afterwards, or set up again!
After resetting the machine control to the factory settings, it is essential that the machine type
used is checked and reset if necessary.
RESET
+
+
+