Design and function
Setting the expert parameters
40
099-005207-EW501
18.05.2017
5.4
Setting the expert parameters
The parameter values set are preset in the JOB and can be modified if necessary.
Operating
element
Action
Result
1 x
Expert parameter selection.
The combination of buttons has to be pressed within 3 seconds.
1 x
2 x
n x
Select Expert parameter:
GvS
Gas pre-flow time (0 to 10 sec)
On
Wire creep speed 1.5 to 20 m/min.
tZn
Ignition time (0 ms to 500 ms)
Int
Operating mode: non-latched interval/latched interval
The display shows the selected parameter.
Set the selected parameter.
5.4.1
Explanation of symbols
Symbol
Meaning
"GnS" - Gas post-flows
"drb" - Wire burn-back
"t1" - Spot time
"t2" - Interval time
"GvS" - Gas pre-flows
"On" - Wire creep
"tZn" - Ignition time
"tyP" - Machine type (type table,
> see 7.2 chapter
)