Machine description
– quick overview
Machine control
– Operating elements
099-005207-EW501
18.05.2017
17
Item Symbol
Description
0
5
Operating mode push-button
> see 5.3 chapter
-------- Non-latched
------- Latched
------ Spot welding
----- Interval/Interval (latched)
6
Operating / Connection element not used in this system!
7
Wire feed speed/welding parameter rotary knob
Infinite adjustment of the wire feed speed/welding parameters and corresponding
values
8
Sequence parameter push-button
--------- Gas post-flow time
------- Wire burn-back
------ Spot time/pulse time
------- Pulse pause
9
Button, Test welding parameters
> see 5.2.1.1 chapter
10
Gas test push-button
> see 5.1.6.4 chapter
11
Push-button, wire inching
Potential- and gas-free inching of the wire electrode through the hose package to the
welding torch
> see 5.1.8.4 chapter
.
12
Lower display
Display of wire feed speed, welding current, sheet metal thickness, JOB number and
runtime parameters.
13
Upper display
Display of the welding voltage, correction value for the wire speed or parameter
designations for runtime parameters.
14
Signal light, MANUAL
Signal light is on when the machine is not in JOB mode. All parameter settings are
carried out "manually" by the user (JOB 0).
15
Signal light, HOLD
Lit:
Display shows the last parameters used for welding.
Not lit: Display shows the setpoint values or current values during welding.
16
Signal light Voltage
On when the welding voltage or open circuit voltage is displayed.
17
Signal light, Wire correction
On when the correction value of the wire speed is being displayed.