Appendix
Parameter overview – setting ranges
66
099-007033-EW501
4.1.2022
10 Appendix
10.1 Parameter overview – setting ranges
Name
Display
Setting range
Co
de
St
and
ar
d
Un
it
min
.
max.
Main current AMP, depending on power source
-
A
-
-
-
Gas pre-flow time
0,5
s
0
-
20
Start current, percentage of AMP
20
%
1
- 200
Start current, absolute, depending on power source
-
A
-
-
-
Start time
0,01
s 0,01 - 20,0
Up-slope time
1,0
s
0,0 - 20,0
Pulse current
140
%
1
200
Pulse time
0,01
s 0,00 - 20,0
Slope time (time from main current AMP to secondary current
AMP%)
0,00
s 0,00 - 20,0
Secondary current, percentage of AMP
50
%
1
200
Secondary current, absolute, depending on power source
-
A
-
-
Pulse pause time
0,01
s 0,00 - 20,0
Slope time (time from main current AMP to secondary current
AMP%)
0,00
s 0,00 - 20,0
Down-slope time
1,0
s
0,0 - 20,0
End current, percentage of AMP
20
%
1
- 200
End current, absolute, depending on power source
-
A
-
-
-
End current time
0,01
s 0,01 - 20,0
Gas post-flow time
8
s
0,0 - 40,0
Electrode diameter, metric
2,4 mm 1,0 - 4,0
Electrode diameter, imperial
92
mil 40 - 160
spotArc time
2
s 0,01 - 20,0
spotmatic time (
>)
200 ms
5
- 999
spotmatic time (
>)
2
s 0,01 - 20,0
Pulse balance
50
%
1
-
99
Pulse frequency
50
Hz
5
- 15000