Design and function
TIG welding
099-007033-EW501
4.1.2022
41
5.3.4 Expert menu (TIG)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
ENTER
EXIT
Figure 5-20
Display
Setting/selection
Expert menu
Start time (duration of start current)
Slope time (main current to secondary current)
Slope time (secondary current to main current)
End current time (duration of end current)
Ignition type (TIG)
-------HF start active (ex works)
-------Lift arc ignition active