Functional characteristics
Special parameters (advanced settings)
099-5TLPXQ-EW501
29.01.2021
57
Display
Setting/selection
Electronic gas flow control, type
1 = ------- type A (ex works)
0 = ------- type B
Program settings for relative programs
0 = ------- Combined setting of relative programs possible (ex works).
1 = ------- Individual setting of relative programs possible (ex works).
Correction or nominal voltage display
0 = ------- Correction voltage display (ex works).
1 = ------- Absolute nominal voltage display.
JOB selection in Expert mode
Without function in this machine version.
Nominal value of wire spool heater (OW WHS)
> see 5.10.1.23 chapter
off = switched off
Temperature setting range: 25°C - 50°C (45°C ex works)
Operating mode switching at welding start
> see 5.10.1.24 chapter
0 = ------- Not enabled (ex works)
1 = ------- Enabled
Error threshold of electronic gas flow control
> see 5.10.1.25 chapter
Error output in case of gas nominal value deviation
Unit system
> see 5.10.1.26 chapter
0 = ------- metric system (ex works)
1 = ------- Imperial system
Selection option for program sequence with rotary knob
> see 5.10.1.27 chapter
0 = ------- Not enabled
1 = ------- Enabled (ex works)
5.10.1.1 Ramp time for wire inching (P1)
The wire inching starts with a speed 1.0 m/min for 2 secs. It is subsequently increased to a ramp function
to 6.0 m/min. The ramp time can be set between two ranges.
During wire inching, the speed can be changed by means of the welding power rotary knob. Changing the
speed has no effect on the ramp time.
5.10.1.2 Program "0", releasing the program block (P2)
The program P0 (manual setting) is blocked. Only operation with P1-P15 is possible, irrespective of the
key switch position.
5.10.1.3 Display mode for Up/Down welding torch with one-digit 7-segment display (P3)
Normal display:
• Program mode: Program number
• Up/down operation: Welding power (0=minimum current/9=maximum current)
Toggling display:
• Program mode: Program number and welding procedure (P=pulse/n=not pulse) are toggled
• Up/down operation: Welding power (0=minimum current/9=maximum current) and symbol for up/down
operation are toggled
5.10.1.4 Program limit (P4)
Program selection can be limited with the special parameter P4.
• The setting is adopted for all JOBs.
• Program selection depends on the position of the "welding torch function" changeover
switch
> see 5.2.16 chapter
.
Programs can only be switched when the changeover switch is in the "program" position.
• Programs can be switched by means of a connected remote control or special welding torch.
• If a special welding torch or a remote control is not connected, it is only possible to switch programs by
means of the "arc length correction/select welding program" rotary dial
> see 4 chapter
.