Function specification
3/2
A1
Rotary switch
The following operating modes can be preselected:
•
Non-latched operation without UP-SLOPE / DOWN-SLOPE
•
Non-latched operation with UP-SLOPE / DOWN-SLOPE
•
Latched operation with UP-SLOPE / DOWN-SLOPE
•
MMA operating mode
B1
0
0
25
UP-SLOPE
UP-SLOPE (current increase)
The increase in current from the ignition current I
s
(E1) to the main current value
I
1
(F1) can be infinitely adjusted between 0-25 sec with this rotary dial.
Definition of UP-Slope and DOWN-Slope:
Rise and fall times are set as angles, the maximum times of 25 sec are reached
when Is = minimum and I
1
maximum are selected. A change e.g. in the welding
current I
1
(broken line) results in a shortening of the UP-Slope and DOWN-
Slope times.