Technical data
Tetrix XQ 230 puls AC/DC
099-005630-EW501
02.03.2021
51
8.3 Tetrix XQ 230 puls AC/DC
TIG
MMA
Welding current (I
2
)
3 A to 230 A
5 A to 190 A
Welding voltage according to standard
(U
2
)
10,1 V to 19,2 V
20,2 V to 27,6 V
Duty cycle DC at 40° C
[1]
35 %
-
190 A
40 %
230 A
-
60 %
200 A
150 A
100 %
170 A
120 A
Mains voltage (Tolerance)
1 x 230 V (-40 % to +15 %)
Frequency
50/60 Hz
mains fuse
[2]
1 x 16 A
Open circuit voltage (U
0
)
96 V
max. Connected load (S
1
)
5,5 kVA
6,5 kVA
Generator rating (Rec.)
8,8 kVA
Power consumption P
0
29 W
Cos φ / efficiency
0,99 / 82 %
Protection class / Overvoltage
category
Ⅰ
/
Ⅲ
Contamination level
3
Insulation class / protection
classification
H / IP 23
Residual current circuit breaker
Type B (recommended)
Noise level
[3]
<70 dB(A)
Ambient temperature
[4]
-25 °C to +40 °C
Machine cooling / Torch cooling
Fan (AF) / gas
Mains connection cable
H07RN-F3G2,5
Workpiece lead (min.)
35 mm
2
EMC class
A
Safety marking
/ /
Standards used
See declaration of conformity (appliance documents)
[1]
Load cycle: 10 min. (60 % DC
≙
6 min. welding, 4 min. pause)
[2]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger chara-
cteristic must be used.
[3]
Noise level during idle mode and operation under standard load according to IEC 60974
‑
1 at the ma-
ximum operating point.
[4]
Ambient temperature dependent on coolant! Observe coolant temperature range!