Rectifying faults
Error messages (power source)
099-005630-EW501
02.03.2021
47
Error (category)
Possible cause
Remedy
56
Mains phase failure
One phase of the mains voltage
has failed.
Check mains connection, mains plug
and mains fuses.
57
B
Slave tacho error
Wire feeder fault (slave drive). Check connectors, cables, connec-
tions.
Permanent overload of the wire
drive (slave drive).
Do not place the liner in tight radii.
Check liner for smooth movement.
58
B
Short circuit
Check welding circuit for short
circuit.
Check welding current circuit.
Place welding torch on an insulated
surface.
59
Incompatible machine A machine connected to the
system is not compatible.
Disconnect incompatible machine
from system.
60
Incompatible software A machine's software is not
compatible.
Request service.
61
Welding monitor
The actual value of a welding
parameter is outside the spe-
cified tolerance field.
Observe tolerance fields.
Adjust welding parameters.
62
System component
[1]
System component not found. Request service.
63
Mains voltage error
Operating and mains voltage
are incompatible
Check or adjust operating and mains
voltage
[1]
only for XQ. machine series
[2]
not for XQ. machine series
[3]
See technical data for values and other switching thresholds
> see 8 chapter
.