Design and function
Special parameters (advanced settings)
100
099-005402-EW501
24.11.2016
"Single or dual operation" (P10) setting
If the system is fitted with two wire feeds, no further accessory components may be operated on
the 7-pole connection socket (digital)!
This relates to digital remote controls, robot interfaces, documentation interfaces, welding
torches with digital control lead connection, etc.
No second wire feed may be connected in single operation (P10 = 0)!
• Remove connections to the second wire feed
In dual operation (P10 = 1 or 2), both wire feed units must be connected and configured differently
on the controls for this operating mode!
• Configure one wire feed unit as the master (P10 = 1)
• Configure the other wire feed unit as a slave (P10 = 2)
Wire feed units with key switches (optional,
> see 5.6 chapter
) must be configured as masters
(P10 = 1).
The wire feed configured as the master is active after the welding machine is switched on. There
are no other functional differences between the wire feeds.
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
JOB list switching (P12)
Value Designation
Explanation
0
Task-oriented
JOB list
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
1
Actual JOB list
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
2
Actual JOB list,
JOB changeover active
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
Creating user-defined JOB lists
A consecutive memory range where accessories such as the POWERCONTROL 2 torch can be
used to switch between JOBs will be created.
• Set special parameter P12 to "2".
• Set "Program or Up/Down function" changeover switch to "Up/Down" position.
• Select an existing JOB which is closest to the required result.
• Copy JOB to one or more target JOB numbers.
If any JOB parameters need to be changed, select the target JOBs in sequence and change the
parameters individually.
• Set special parameter P13 to the lower limit and
• Set special parameter P14 to the upper limit of the target JOBs.
• Set "Program or Up/Down function" changeover switch to "Program" position.
JOBs can be changed over in the specified range using the accessory component.