Design and function
Interfaces for automation
90
099-005402-EW501
24.11.2016
5.9.2
Remote control connection socket, 19-pole
Figure 5-72
Pin
Signal form
Short description
A
Output
Connection for PE cable screen
C
Output
Reference voltage for potentiometer 10 V (max. 10 mA)
D
Input
Control voltage specification (0 V
–10 V) – wire feed speed
E
Output
Reference potential (0 V)
F/S
Input
Welding power start/stop (S1)
G
Input
Control voltage specification (0 V
–10 V) – arc length correction
P
Input
Activation of control voltage specification for wire feed speed (S2)
For activation, put signal to reference potential 0 V (pin E)
R
Input
Activation of control voltage specification for arc length correction (S3)
For activation, put signal to reference potential 0 V (pin E)
U/V
Output
Supply voltage push/pull welding torch