HPS-C - TS operating instructions
Page 10 / 32
Zone selection / grouping
The set value can only be adjusted in the Display menu if the relevant zones have been selected beforehand. The selected
zones are marked with a green frame, in order to enable them to be more quickly identified. Both single and several or all
zones can be selected or grouped.
The selection or grouping can be carried out in several ways:
•
Selection of a single zone by touching the zone window.
•
Selection of any combination of several zones by touching the corresponding zone windows. Only zones set in the
same operating mode ("°C" / "%" / "A“) can be selected together.
•
Grouping of several consecutive zones. The first and last zones required are selected; all zones between these are
then also selected by pressing the "GROUP" key. This enables e.g. set value changes to be made for a whole nozzle
group.
•
Grouping of all available control zones. The first and last zones of the control system are selected; the complete
selection can then be made using the "GROUP" key.
After all the required zones have been selected and grouped, the "SET" key can be used to open the input window and to
make the required set value change.
The zone selection / grouping is then individually cleared by touching the screen or is completely cancelled using the
"CLEAR" key.
If necessary the grouping can be retained. It is useful if e.g. to open single nozzles in a high cavity system with a higher set
value (" + " function in the input window) and must be removed again after starting up (" - " function in the input window). Any
differing set values of the zones are then reset to the basic setting.
Alarm messages
If errors occur and are detected by the control system the affected zones are displayed with a red frame to enable them to
be immediately recognised. In addition, an "ALARM" message is output in the status bar, so that errors in zones on any
other pages can also be recognised. After pressing the "Alarm" key or touching the alarm message the alarm window is
opened, in which all currently queued error messages are displayed in plain text. The alarm window can also be opened
from all other menus.
Corrected errors are acknowledged here in order to reset the alarm message. If sufficient information is available the window
is closed using the corresponding button.
All errors that have occurred since the control system was switched on are saved in the error log book of the control monitor
and can be opened under the "Options" menu.
Zone with error
display
Alarm window
Alarm message