HPS-C - TS operating instructions
Page 28 / 32
Connector pin and terminal assignment
24 V DC signal socket
Contact / Wire Name
Use
1
Input 1
Decrease
2
Input 2
Increase
3
Input 3
Not used
4
Input 4
Not used
5
Output 1
Fault message
6
Output 2
Warning message
7
Output 3
Hotrunner ON
8
Output 4
Not used
9
+ 24 V DC
Power supply
10
GND
for the inputs
11
-
-
12
PE
Protective conductor
Each output can be loaded with max. 200 mA, the total load of the connection plug however must not exceed 0.5 A.
All inputs and outputs operate on the 24V DC voltage level.
230 V AC signal socket
Contact Use
1
230 V (via unit switch)
2
Fault message 230 V
3
Warning message 230 V
4
Neutral conductor N
PE
Protective conductor
Each output can be loaded with max. 0.5 A, total load max. 1 A.
The signals are directly available with voltage level 230 V AC.
Communication interface CAN (connector and socket)
Use
1
-
2
CAN_L
3
CAN_GND
4
-
5
-
6
GND (24 V)
*)
7
CAN_H
8
-
9
+ 24 V DC
*)
*) For power supply of the control panel or the touchscreen monitor, applied only in the direct connection.