6.6 SHUTDOWN OF POWER BRANCH
According to IEC 61851, a shutdown of the power branch on completion of the charging process within 3 s is
required. A shutdown of the power branch on transition from state C to state A is required within 100 ms. The
Viridian EPC 2.0 deactivates the relay output within this requirement after detecting the shutdown criterion.
WARNING: THE SHUTDOWN OF THE POWER BRANCH, IN PARTICULAR THE POWER
CONTACTOR, IS TO BE DESIGNED IN SUCH A WAY THAT THE ENTIRE IMPACT CHAIN DOES
NOT EXCEED THE REQUIRED 100 MS.
F
ailure to observe this notice can result in death or serious physical injury.
6.5 FUNCTIONAL GROUNDING
VEHICLE INTERFACE ACCORDING TO IEC 61851
1.
Connect the terminals
“
CP
”
and
“
PP
” (
on free cable versions only) directly to the EVSE socket
2.
First connect the ground connection of the vehicle interface to the 0V reference point and then route this
potential from there
DANGER: NEVER USE THE TERMINALS OF THE VIRIDIAN EPC 2.0 CHARGING
CONTROLLER AS A 0V REFERENCE POINT.
Always route this externally from the device! The 0V reference point within the plant must be
6.4 EXTERNAL LED CONNECTOR
An external RGB LED can be driven by the EPC 2.0. It is 0V active with common 12V. A wiring harness and connect-
or on one end will be an optional extra with the EPC 2.0 that can be cut to length by user and connected to their
chosen LED.