3704-IG-001 Installation and User Manual
Page 27
Status Indicator Chart
(Power)
(Connected) (Charging) (Problem)
NORMAL USE MODES:
BLUE
YELLOW
GREEN
RED
1
Line Voltage On
F/2
F/2
F/2
F/2
2
Self-Diagnostics Pass
Line Voltage is between 208-240VAC
Ground Connection Present
ON
X
X
X
3
Waiting to connect to EV
ON
SF
X
X
4
Cable is connected
ON
ON
X
X
5
Random start time activated – Charging
begins in 2-5 minutes
ON
X
SF
X
6
Vehicle in charge mode (Level 2)
ON
X
FF
X
7
Vehicle charged
ON
X
ON
X
8
Cable is connected/standby mode (ext. contact) (Level 1
charge)
ON
SF
SF
X
9
Cable is connected/off mode (ext. contact)
ON
FF
FF
X
FAULT MODES:
1
Ground wire is NOT connected
FF
X
X
ON
2
Line Voltage Is less than 208VAC
SF
X
X
SF
3
Clutch/Cable Motor Failure
X
SF
X
ON
4
GFCI Trip (reclosure in process)
SF
SF
X
SF
5
GFCI Trip
SF
SF
X
ON
6
GFCI Circuit Failure
SF
X
X
ON
7
Over Current Trip
FF
FF
X
ON
8
Stall Trip (reclosure in process)
ON
SF
X
SF
9
Stall Trip
ON
SF
X
ON
10
Pilot Problem
ON
ON
X
SF
11
Ventilation Required
ON
X
X
SF
12
Display Offline (comm. problem with sequencer)
FF
X
X
X
13
Load/No Load Voltage Differential Problem
X
X
X
FF
PROGRAM MODES:
1
In Program Mode
SF
<--
SF
<--
SF
<--
SF
<--
2
Program Completed/program connector attached
ON
ON
ON
ON
Legend
F/2 = Flash once for 2 sec. X = Led is off
SF = Slow flash (1/sec) <-- = In Sequence
FF = Fast flash (3/sec)