3704-IG-001 Installation and User Manual
Page 10
308.3.1 Side Reach – Unobstructed
Where a clear floor or ground space allows a parallel
approach to an element and the side reach is
unobstructed, the high side reach shall be 48 inches (1220
mm) maximum and the low side reach shall be 15 inches
(380 mm) minimum above the finish floor or ground.
Figure 3D
308.3.2 Side Reach – Obstructed High Reach
Where a clear floor or ground space allows a parallel
approach to an element and the high side reach is over an
obstruction, the height of the obstruction shall be 34
inches (865 mm) maximum and the depth of the
obstruction shall be 24 inches (610 mm) maximum. The
high side reach shall be 48 inches (1220 mm) maximum for
a reach depth of 10 inches (255 mm) maximum. Where
the reach depth exceeds 10 inches (255 mm), the high side
reach shall be 46 inches (1170 mm) maximum for a reach
depth of 24 inches (610 mm) maximum.
Figure 3E
309 Operable Parts
309.1 General – Operable parts shall comply with 309.
309.2 Clear Floor Space – A clear floor space or ground
space complying with 305 shall be provided.
309.3 Height – Operable parts shall be placed within one or
more of the reach ranges specified in 308.
309.4 Operation – Operable parts shall be operable with
one hand and shall not require tight grasping, pinching, or
twisting of the wrist. The force required to activate
operable parts shall be 5 pounds maximum.
NOTE: In order to remain ADA-compliant, from the user’s perspective, the center of the 3704’s Data Router MUST be no
more than 48 inches from the ground when mounted to the pole, regardless of how the pole is mounted to the
ground, or to a wall (Figure 1B).