3704-IG-001 Installation and User Manual
Page 20
Wiring the EVSE for Serial Connections
1.
Feed the Payment Module communication cables for EVSEs through either the serial cable access hole in the back
of the EVSE if mounted to a pole (Figure 11), or the right knockout (Figure 7A) on the bottom of the EVSE.
2.
Pull the Payment Module communication cables carefully through the access hole so there is enough slack to work
with.
3.
Keeping in mind that the right EVSE is # 1, when looking at the access cutout hole (Figure 9A) or the mounted
Payment Module (Figure 1B), attach each individual wire of the Payment Module communication cable to its
corresponding, pre-wired counterpart in the 5-position Euro-Block (Figure 12).
4.
Repeat Steps 1-3 to wire EVSE # 2’s Payment Module communication cable
to its corresponding, pre-wired counterpart in the 5-position Euro-Block.
Final Wiring Between Payment Module and EVSE:
Payment Module Wiring
EVSE Wiring
Position
Function
Position
Function
1
24 VDC
1
Not Used
2
REC (in from EVSE)
2
24 VDC
3
XMIT (out to EVSE)
3
TXD / XMIT (out to Payment Module)
4
GND
4
RXD / REC (in from Payment Module)
5
SHIELD
5
Ground
Position
Function
Wire Color (As
Depicted. Reference
Only)
1
Shield
Shield/Drain
2
24 VDC
Red
3
XMIT (out to Module)
White
4
REC (in from Module)
Black
5
GND
Green
Figure 12
Wire Here
Serial Cable access hole for
pole mount
Serial Connection
Terminal Block
Figure 11