Barrier M
Technical Data
4.
39
4.3
Controller
4.3.1
General data
Housing
Protection rating
IP 43
Material
Sheet steel, painted or stain-
less steel
Color shade
RAL 7035
Max. sound pressure level
control cabinet 1125 x 800 x 400
65 db
control cabinet 700 x 500 x 300
62 db
Ambient conditions
Ambient temperature
+5 ... +40°C
Environment
No direct sunlight, protected
against rain
Installation height
Max. 2,000 m
Storage temperature
-20 ... +80°C
Digital input signal
•
Release contact for swit-
ching on and off
•
Disinfection MIN
Switching to maximum UV
lamp power
Analog input signal
•
UV sensor (4 - 20 mA)
•
Flow rate (4 - 20 mA)
•
SEC 254 (4 - 20 mA)
•
for recording the water tem-
perature (Pt100)
•
for recording the motor
position (impulses)
Analogue output signal
•
for UV intensity
(4-20 mA)
Accuracy: +/- 5% relative to
measurement/calculated
value
Содержание WALLACE & TIERNAN Barrier M 1200
Страница 1: ...WALLACE TIERNAN UV DISINFECTION UNIT BARRIER M OPERATING MANUAL...
Страница 2: ...2 WT 090 370 000 DE IM 0715 Barrier M Please note Original manual...
Страница 96: ...96 WT 090 370 000 DE IM 0715 Spare parts maintenance schedule Barrier M 6...
Страница 100: ...100 WT 090 370 000 DE IM 0715 Table of UV alarm levels Barrier M 7...
Страница 102: ...102 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Страница 103: ...Barrier M Certificates declarations and statements 8 103 8 2 QPS certificate...
Страница 104: ...104 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Страница 105: ...Barrier M Certificates declarations and statements 8 105 8 3 NSF certficate...
Страница 106: ...106 WT 090 370 000 DE IM 0715 Certificates declarations and statements Barrier M 8...
Страница 109: ...Barrier M 109...