19
2551868A
ModuSat® Wiring Connections
The ModuSat® wiring boards is located within the ModuSat® itself under a removable metal cover.
CHHC has two wiring boards, one for the heating and one for the cooling. Depending on the model,
the boards can be found in either metal boxes shown below.
To access the connection board, take off the cover. The retaining screw should be removed and the
cover lifted off. The connection board will then be accessible and all required connections can be
made simply using the clearly labelled screw down terminal connections. Guides for the various
connection applications and requirements are detailed in the wiring principle drawings shown on
pages 21-23.
The Control Board
The control board is located next to the connection board. The control board cover must
not be removed. Doing so may invalidate the warranty.
Connection Terminations
Evinox Energy strongly recommend in accordance with best practice that all wiring
connections to the board, especially the BUS and room controller are terminated using
‘bootlace ferrule’ connectors. These connectors ensure a good connection and that the
whole cross sectional area of the wiring is intact.
5.2.1
RJ45 Connections
If the TCP/IP network is used (instead of the BUS) the RJ45 must be connected to the control board.
The RJ45 connection can be found at the bottom of the control board as shown below.
Cable glands are fitted at the bottom of the ModuSat® case as shown in below: