IE-SNC-Tx5xx-03
7
Figure 4. – connection of the T4511 transducer
Power voltage
Power voltage: 9 to 30Vdc, maximum consumption 200mA, connector coaxial, diameter
5 x 2.1 mm, positive pole is the central pole.
Installation
It is necessary to assign a new suitable IP address to the device at the first connection to it in
order to prevent collisions with already existing network IP addresses, and make the address
conform with the local habits. If installing several new devices, connect them to the network one
after another! If a suitable IP address is not known, contact your network administrator and ask him
for the following:
IP address:
_____._____._____._____
IP gate address:
_____._____._____._____
Mask of network:
_____._____._____._____
The IP gate address and the network mask need not be specified if the device will be
operated only in a local network. If you set the IP address to one which is already used in the
network the device will not work correctly and collisions in the network will appear.
The IP address of each device is set by the manufacturer to
192.168.1.213.
Installation procedure
•
run a Tx5xx_setup.exe
•
set a new IP address of the device (default IP address is 192.168.1.213)
•
configure the device in accordance with your requirements (alarm settings, sending of e-
mail, traps…)
•
store the settings
See more details about use of the Setup in chapter Setting of device – Setup, page 17.