HD9010TM High Definition Time Code Master Manual
OPERATION
Revision 2.4.1
Page 3-11
Press the
ENTER
key to recall the last User Bits that you entered into the generator. The display
prompt at the left of the display will blink while data entry mode is active, and the dual functioned keys
are now changed to their numeric values. If you want to re-enter these User Bits press the
ENTER
key
to complete the data entry into the generator.
Pressing any numeric key will clear the previous value and place the new value into the numeric
display, starting at the right. Pressing the
SHIFT
key and the numeric keys 0 to 5 will enter the
corresponding hexadecimal values A to F. Un-entered digits are assumed to be zero. When the
required number of digits are entered, press the
ENTER
key to complete the data entry into the
generator User Bits.
Attempts to enter too many digits will result in the display being blanked. Re-enter the correct value
and press the
ENTER
key. Pressing the
ESC
key will cancel the data entry mode without changing
any data.
The numeric keys return to their normal functions when the data entry has been completed by pressing
the
ENTER
key or cancelled by pressing the
ESC
key. The display prompt will return to its steady On
state when data entry mode has been completed.
Numeric entry mode must be terminated (GUB will be On steady) before any of the
front panel keys will resume normal operation.
3.4.4. Jam Syncing the Generator to the Primary reader
Pressing the
JAM
key transfers the primary reader’s time into the generator clock, and then releases the
clock to run on its own. This mode is known as
Momentary Jam Sync
. (See section 3.5.1 for
information about selecting the primary reader.)
The generator time may be continuously slaved, or 'Jam synced' to data coming from the primary
reader by pressing the
SHIFT+JAM
keys. This mode is known as
Continuous Jam Sync
. The JAM
LED will be on when
Continuous Jam Sync
mode is enabled. Pressing the
SHIFT+JAM
keys again
terminates the
Continuous Jam Sync
mode.
Jam sync mode should be used when you need to generate ancillary time code that follows an LTC
source time code. In this mode the HD9010TM will function as an LTC to ATC translator.
Jam sync mode should also be used when dubbing longitudinal time code from one tape to another, as
the quality of the time code signal deteriorates with each generation, and will become unusable after the
third generation.
When the time information is being jammed the generator and primary reader’s times are compared
with each other during each frame, automatically compensating for the value programmed into the
OFFSET
register. If for any reason they are not equal, the jam is bypassed, and the generator
substitutes the next frame number. The
JAM
indicator will blink off when a jam error is encountered. If
the number of consecutive jam bypass errors exceeds 5, the last valid primary reader’s time is jammed
into the generator again with the programmed
OFFSET
. In the absence of valid reader data within the
last 5 frames, the generator operates according to the programmed
NO CODE JAM
mode (
HOLD
=
generator stops;
RUN
= generator increments normally; or
MUTE
= generator turns off) until valid
reader code resumes. At this time it will be re-jammed to the reader, thus repairing large dropouts on
the reader tape. (See section 3.4.9 for a full description of the
NO CODE JAM
modes.)
Содержание HD9010TM
Страница 2: ...This page left intentionally blank ...
Страница 6: ...HD9010TM High Definition Time Code Master Manual Revision 2 4 1 This page left intentionally blank ...
Страница 10: ...HD9010TM High Definition Time Code Master Manual Page iv Revision 2 4 1 This page left intentionally blank ...
Страница 12: ...HD9010TM High Definition Time Code Master Manual Revision 2 4 1 OVERVIEW This page left intentionally blank ...