HD9010TM High Definition Time Code Master Manual
Page 3-8
Revision 2.4.1
OPERATION
Turn the
SHAFT ENCODER
knob to change the value of the displayed parameter. When the value
shown is not the active value the display will stop blinking. When you have selected the desired
parameter value press the
SELECT
key to make that value the active value. (The display will start
blinking again). Press the
ESC
key when the display is blinking to move back up the menu to the top
saving your selection. You can press the
ESC
key when the display is not blinking to move back up the
menu to the top level without saving your selection. You can select other menu items from the top level
by turning the
SHAFT ENCODER
knob, followed by the
SELECT
key. Alternately you can exit the
setup menu and return to the normal
DISPLAY
mode by pressing the
ESC
key.
Figure 3-2 gives an overview of the setup menu. Sections 3.4 to 3.7 provide detailed descriptions of the
GENERATOR, READER, VCG
and
UTILITY SETUP
menus. The tables in these sections are
arranged in an indented structure to indicate the path taken to reach the control.
3.4.
CONFIGURING THE GENERATOR
The
GENERATOR SETUP
menu is used to set up various generator modes such as selecting Drop
Frame, Jam Sync Modes, ATC Generator Line number, whether user bits contain static numbers or
time information, etc. The chart below shows the items available in the
GENERATOR SETUP
menu.
Sections 3.4.1 to 3.4.9 give detailed information about each of the sub-menus.
GEN MODE
Sets the operating mode of the LTC and ATC generators
GEN ATC TYPE
Selects whether LTC or VITC or both ATC packets will be inserted
GEN DROP FRAME
Configures the generator drop frame mode
GEN LTC PARITY
Configures the parity of the LTC generator
GEN NO CODE JAM
Configures the action when input code is missing and the HD9010TM is
in continuous JAM sync mode
Table 3-1: Top Level of the Generator Setup Menu
Содержание HD9010TM
Страница 2: ...This page left intentionally blank ...
Страница 6: ...HD9010TM High Definition Time Code Master Manual Revision 2 4 1 This page left intentionally blank ...
Страница 10: ...HD9010TM High Definition Time Code Master Manual Page iv Revision 2 4 1 This page left intentionally blank ...
Страница 12: ...HD9010TM High Definition Time Code Master Manual Revision 2 4 1 OVERVIEW This page left intentionally blank ...