4.8.2. Flow Redundancy Configuration
1- Revertible
- In this mode, when the flow fails over to backup, it will remain on the backup path
until the main path heals. When the main path is healed, the output will switch back to main.
2- None-revertible
– In this mode, when the flow fails over to backup path, it will remain on the
backup even when the main path heals. Then when the backup path fails, the unit will switch back
to the main path.
3- Force to Main
- In this mode, when the flow fails over it is forced to main and will remain.
4- Force to Backup-
In this mode, when the flow fails over it is forced to backup and will remain.
4.9. SFP NOTIFY
Figure 4-30: WebEASY
®
-SFP Notify
4.9.1. Notify
For Destination 1 to 5
Trap Destination
: This control is used to specify the trap address for sending out trap messages for
Link Status
faults and
SFP
faults.
4.9.2. Port
For SFP 1 to 12
Trap alarms can be enabled (True) or disabled (False) for
Port Link
, and SFPs operating outside of a
designated range (set in the system menu, see section 4.1.8).