47
F22
1
10
s
10
10
Time cue at the evaporator fan switching-on
F23
0
100
%
0
0
Calibration value of the evaporator fan minimum speed
F24
0
100
%
100
100
Calibration value of the evaporator fan maximum speed
F25
-50
99
°C
99
99
Temperature for evaporator fan stop
Par.
Min.
Mas.
Unit
Dough
Retarder-Proofer
Digital inputs
i0
0
2
¬¬¬¬
1
1
Effect caused by the door opening, i.e. by the micro door input activation 0 = no effect
1 = the compressor, the evaporator fan and the heating resistors will be switched off,
the cell light will be switched on 2 = the evaporator fan and the heating resistors will be
switched off . The cell light will be switched on
i1
0
1
¬¬¬¬
1
1
Type of contact of the micro door input 0 = normally-open (active input with closed con-
tact) 1 = normally-closed (active input with open contact)
i2
¬1
120
min
-1
-1
Delayed alarm warning when the door is open (code “
id
”) -1 = the alarm is not reported
i3
0
1
¬¬¬¬
1
1
Effect caused by the activation of the high pressure input 0 = no effect 1 = the compres-
sor and the evaporator fan will be switched off and the condenser fan will be switched
on
i4
0
1
¬¬¬¬
0
0
Type of contact of the high pressure input 0 = normally open (active input with closed
contact) 1 = normally closed (active input with open contact)
i5
¬1
240
s
5
5
High pressure delayed alarm warning (code “
HP
”) 1 = the alarm is not reported
i6
0
2
¬¬¬¬
1
1
Effect caused by the activation of the low pressure input 0 = no effect 1 = alarm. The
compressor and the evaporator fan will be switched off , 2 = pumpdown management
and alarm. During the compressor switching off the intervention of the digital input will
switch off the compressor output because of the pumpdown end-of-phase . During the
activation of the cooling system, the intervention of the digital input will switch off the
compressor and the evaporator fan.
i7
0
1
¬¬¬¬
0
0
Type of low pressure input contact 0 = normally open (open input with closed contact) 1
= normally closed (active input with open contact)
i8
¬1
240
s
10
10
Low pressure delayed alarm warning (code “LP”) 1 = the alarm is not reported
i9
0
240
s
40
40
Low pressure limiter reset time when the compressor is being switched on (if i6 = 2 only)
i10
0
1
¬¬¬¬
0
0
Type of contact of the thermal protector input 0 = normally open (active input with closed
contact) 1 = normally closed (active input with open contact)
i11
¬1
240
s
5
5
Thermal protector delayed alarm warning (code “CtH”) 1 = the alarm is not reported
Par.
Min.
Mas.
Unit
Dough
Retarder-Proofer
Digital outputsi
u1
0
1
¬¬¬¬
1
1
Utility managed by the K8 output 0 = pump down valve (in this case the u2 parameter
will be significant) 1 = evaporator fan (in this case the output will repeat on ON/OFF
mode the PWM output status dedicated to the evaporator fan)
u2
0
240
s
10
10
If i6 = 0 or 1: compressor delayed deactivation from the pump down valve switching off
(pump down in shutdown, for u1 = 0 only) If i6 = 2: Maximum duration of pumpdown in
compressor shutdown without the activation of the low pressure input so as to cause
the compressor switching off and the pumpdown alarm warning 0 = the alarm is not
reported
u3
0
1
¬¬¬¬
1
1
Utility managed by the K4 output0 = dehumidifier /extraction fan (in this case the rU5
and rU6 parameters will be significant) 1 = condenser fan (in this case the F16 and F17
parameters will be significant)
PLEASE NOTE
: with u3 = 1 the dehumidifier activity is
automatically managed by the activation of the cooling system
Par.
Min.
Mas.
Unit
Dough
Retarder-Proofer
Serial communication (serial door RS485 with MODBUS communication
protocol)
L1
1
240
min
5
5
Sample time of internal data
LA
1
247
¬¬¬¬
247
247
Device address
Lb
0
3
¬¬¬¬
2
2
baud rate 0 = 2.400 baud 1 = 4.800 baud 2 = 9.600 baud 3 = 19.200 baud
LP
0
2
¬¬¬¬
2
2
Even parity 0 = none (no parity) 1 = odd (odd) 2 = even (parity)
Par.
Min.
Mas.
Unit
Dough
Retarder-Proofer
Others
E8
0
2
¬¬¬¬
0
0
Key lock 0 = disabled 1= manual 2 = automatic after 1 minute of inactivity during a cycle
E9
0
1
¬¬¬¬
0
0
Visualisation of splash screen EVCO on restoration of power supply 0 = black screen 1
= splash EVCO
E10
0
1
¬¬¬¬
0
0
Display positioning 0 = the device is placed above unit 1 = the device is placed below
unit
E11
0
120
s
10
10
Duration of the buzzer signal during the precooling and the end-of-cycle phase
E12
0
1
¬¬¬¬
0
0
reserved
E13
0
1
0
0
Unlock humidifier management with serial control
E14
0
1
1
1
Enable the block phase in case of automatic programs
E15
0
1
0
0
Reserved
E16
0
0
0
0
Reserved