9
ENGLISH
CHAPTER 9 CONTROLS
Description of control Panel:
The Control Panel consists of a digital capacitive-type temperature controller for coldness with colour
3,5” TFT supplied with user-friendly icons:
6
7
8
9
11
10
1
2
3
4
5
ESC
The Control Panel is supplied with the following buttons:
1
ON / OFF It allows to change the controller’s status
2
MENU
It allows to open the pop-up window containing the options for the current screen
3
HOME
It allows to go back to the pre-selection screen at any time, cancelling any pro-
cessing selected programme.
4
ESC
It allows to go back to the previous page at any time, cancelling any processing
selected programme.
5
START / STOP
It allows to start/stop a working cycle, either manual or automatic or
auxiliary.
6
MANUAL KEY
It allows to select a MANUAL working cycle
7
PROGRAMMES KEY
It allows to select and/or change automatic retarded proofing
processes stored in memory.
8
FAVOURITE KEY
It allows to recall the last 10 cycles performed promptly.
9
AUTOMATIC KEY
It allows the selection, the setting and the implementation of a com-
plete automatic retarded proofing process.
10
PRE-COOLING KEY
It allows the implementation of a cell pre-cooling cycle.
11
INTERACTIVE SELECTION KEY
It allows to select the menu options