Procedure for filling Propane cylinders equipped with an OPD (Overfill Protection Device) valve
1.
Only permit qualified trained personnel to fill the propane cylinders.
2.
Stop the vehicle prior to entering the fuel station and turn off the propane gas supply valve at the
propane cylinders. Turn off all propane appliances, extinguish all open flames, and verify all pilot
lights are off.
3.
Shut off tow vehicle and extinguish all pilot lights and turn off all appliances prior to filling tanks.
4.
Extinguish all cigarettes, cigars, or pipes.
5.
Ensure that the valve on the cylinder is in the closed position.
6.
Attach the fill hose to the cylinder tank outlet.
7.
Turn on the propane supply source.
8.
Open the bleeder valve screw on the LP tank by 10 percent.
9.
Slowly open the cylinder bottle hand wheel valve approximately one-quarter turn.
10.
As the cylinder begins to fill, the hand wheel valve may be opened further. Opening one full turn is all
that is necessary to fill the tank.
11.
When the bleeder valve begins to spit liquid, shut off the LP fill source, close the bleeder valve screw
on the cylinder then close the valve.
12.
Do not relight the appliances until you have driven at least ½ mile from the fill station.
Propane cylinders, regardless of size, shall never be filled to more than 80% of capacity. Never
attempt to connect or use natural gas to this system. Failure to follow these rules may result in a
failure or event causing significant injury or death.
PLUMBING SYSTEMS
The plumbing system in your trailer is typically categorized into three primary sub-systems: Fresh water, Gray water, and
Black water.
Fresh or Potable water is stored in the fresh water tank or is directly introduced into the plumbing system by way of
the city water fill located on the exterior of the trailer.
Gray water system consists of the waste water from the sinks and tub/shower.
Black water system consists of the waste water from the toilet.
Road vibrations, and shock as well as excessive water pressure from city water sources are the main physical causes of water
system damage. It is important to frequently inspect all plumbing fittings and joints for water seepage. Many times a minor
leak is easily corrected merely by hand tightening the plastic fittings. Do not over tighten the fittings.
NOTICE
Water leakage from plumbing joints may result in considerable damage if left unchecked. It is the
owner’s responsibility to promptly take necessary action to lessen damage due to water leakage
.
FRESH WATER AND WATER PUMP SYSTEM
The fresh water tank may be filled from the exterior water fill by inserting an open-end garden hose into the city water fill
then filling until the monitor panel indicates the tank is full. Only open the valve on your garden hose faucet about 50%
when filling the fresh water tank. do not fill the fresh water tank at full volume/pressure of your garden hose as full volume