63
Network Loss:
Figure 5-20 Alarm & Event Menu – Event – Network Loss
Log:
Check box to record events in the log.
Buzzer:
Check box to enable buzzer when network is lost.
Alarm Output:
This will transmit a signal through one of the alarm outputs. It can be set to either “
NONE
”
(not active), “
1
”, “
2
”, “
3
”, or “
4
”.
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “
Enter
” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration:
The amount of time the buzzer sounds when DVR stops recording. Duration selectable
from 1 to 150
seconds.
Содержание PARAGON 264x4-16
Страница 1: ...Instruction Manual PARAGON 264x4 16 Digital Video Recorder Firmware Version 2 5 5...
Страница 107: ...101...
Страница 108: ...102...
Страница 118: ...112...
Страница 123: ...117 c Click Delete button...