47
Pre-alarm Record:
Check the box to record several moments (approx. 2 ~ 10 seconds) before the motion
event. The pre-alarm recording rate follows the “
Normal
” frame rate setting (Camera Menu).
Buzzer:
Check box to enable buzzer when a motion event is triggered.
Email Notify:
Check box to send email notification when a motion event is detected.
Network Alarm:
Check box to send out a network alarm to client PC when motion occurs. (This function
requires the optional PowerCon 4.x network management software as well as setting up the alarm server in
the Network Setup menu)
Auto Lock:
Check the box and the events will be recorded in the write protected segment of the Hard Disk.
(DVR will lock a period of time when alarm happen, the length of time will depend on DVR setting)
Alarm Output:
This will transmit a signal through one of the alarm outputs. It can be set to either “
NONE
”
(not active), “
1
”, “
2
”, “
3
”, or “
4
”.
Output Type:
Output action when motion is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will remain on until user presses “Enter” key on front panel.
Transparent: Alarm output continues as long as there is a motion event.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration:
Time duration selectable from
1 to 150 seconds.
Edit Motion Grid:
Press this button to edit the motion grid (See
Figure 5-6 Camera Menu – Motion Grid Setting
).
Sensitivity: Set the threshold value for sensitivity. Select from 1 (lowest) to 10 (highest).
Min Area:
To avoid false detections by small objects this value defines, how many grids have to be
detected for generating a motion event. Select a value between 1 (default) to 5 grids.
Delay:
Filter function for avoiding false alarms (set to 1 for the easiest trigger)
Preview: Turn off display for motion grid
Set All: Press this button to select the entire area.
Clear All: Press this button to clear all the grids selected.
Save & Back: Press this button to save the motion grid setting and return to motion setting menu.