Record Stop:
Figure 5-19 Alarm & Event Menu – Event – Record Stop
Log:
Check box to record events in the log.
Buzzer:
Check box to enable buzzer when DVR stops recording.
Email Notify:
Check box to enable email notification when DVR stops recording.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output:
This will transmit a signal through one of the alarm outputs. It can be set to either “
NONE
”
(not active), “
1
”, “
2
”, “
3
”, or “
4
”. (If an output is assigned to Record Stopped, any other events assigned for
that alarm output will automatically change to “None”)
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “
Enter
” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration:
The amount of time the buzzer sounds when DVR stops recording. Duration selectable
from 1 to 150
seconds.