EQ610s
4
2.1.3 BACK PANEL
GN
D
D
/N
Out
D
/N
In
Motion
RS
485
-
RS
485
+
2
3
4
5
6
7
8
LINE IN
1
GN
D
D
/N
Out
D
/N
In
Motion
RS
485
-
RS
485
+
2
3
4
5
6
7
8
AC 24V /
DC 12V
1
+ -
12 VDC / 24 VAC~ Model
90-260 VAC~ Model
Side Panel:
1)
Terminal Block
-GND:
Ground pin
-D/N Out (Day/Night control output):
When the camera is in Day mode,
it will send out a low-level signal of 0V to the external device. When the
camera is in Night mode, it will send out a high-level signal of 3.3V to
the external device.
-D/N In (Day/Night control input):
Please set the D/N limit switch to
OFF, so that the camera can receive an external Day/Night signal (for
example, from a device on the housing) and synchronize the external
device’s Day/Night mode with that of the camera.
-Motion:
Alarm output for in case motion is detected.
If the alarm output is connected and a motion is detected, the message
“MOTION DETECTED” will appear on the screen and the camera will
also send out a high-level signal of 3.3V to the alarm output. As long as
no motion is detected, a default low-level signal of 0V will be
maintained to the alarm output.
-RS485-/RS485+:
Connect to an RS485 cable for keyboard control.
2)
Left-scroll button
3)
Up-scroll button
4)
Set button (push to activate OSD)
5)
Right-scroll button
9