31
Lower reed-switch (58):
• To check the perfect functioning of the lower reed-switch (58), proceed similarly as the upper reed-
switch (54) test, but checking the continuity of the terminal (E) of the circuit board (62) with the aid of
an ohmmeter.
End of cycle microswitch (59):
• To check the end of cycle microswitch (59), use the ohmmeter on terminal (F) of the circuit board (62)
and manually engage the rod at the end of cycle microswitch (59), confirming its perfect functioning.
Movable water sensor (55):
• The movable water level sensor (55) is checked via terminal (C) of the circuit board (62),
performing a direct link between the terminals on the fixed (67) and mobile (55) sensors. In this
condition, there should be continuity in the ohmmeter's reading.
3.4.1 B - COMPONENTS CONTROLLED
BY THE CIRCUITBOARD
• Tighten the screw on the gear lever arm (42) and make use of a voltmeter to check the components
below.
By-pass gas solenoid valve (28):
• With the pointer of the voltmeter on the terminal (H) of the circuit board (62), restart the equipment.
In up to 8 seconds, it should indicate 220V. If it does not, replace the circuit board (62).
Gear motor (60):
• As the running time of the gear motor (60) is controlled by the circuit board (62), and this period is
relatively short, proceed as follows: Position the pointers of the voltmeter on the terminal (J) of the
circuit board (62) and restart the equipment. After approximately 45 seconds, the gear motor (60) will
be switched on. Check if there is voltage (220V) in the terminals (J) of the circuit board (62) If there is
not, replace the circuit board (62).
Water solenoid valve (63):
• After the cleaning cycle, the trough (35) returns to the highest position and, at this time, the circuit
board (62) will switch on the water solenoid valve. With the pointers of the voltmeter, check for voltage
(220V) of the terminal (C) on the circuit board (62). If there is not, replace the circuit board (62).
Micro gear motor (57):
• During the ice formation cycle, check for voltage (220V) on the terminal (L) of the circuit board (62). If
there is not, replace the circuit board (62).
Содержание EGC 100 A / 150 A
Страница 12: ...OVERVIEW EGC 50A COVER COOLING SYSTEM...
Страница 13: ...OVERVIEW EGC 75A EGC 100A AND EGC 150A In the EGC 150A model there are two compressors and two fans...
Страница 14: ...13 I OVERVIEW EGC 150MA I...
Страница 15: ...14 COOLING SYSTEM EGC 50A EGC 75A EGC 100A AND EGC 150A I COOLING SYSTEM EGC 150MA I...
Страница 16: ...ELECTRICAL ELECTRONIC PART...
Страница 17: ...TROUGH DISPLACEMENT SYSTEM DISPLACEMENT ARM ASSEMBLY TROUGH...
Страница 36: ...35...
Страница 37: ...36 EVEREST REFRIGERA O IND E COM LTDA RESERVES THE RIGHT TO MAKE CHANGES TO ITS EQUIPMENT WITHOUT PRIOR NOTICE...