C-PRO MEGA RACK & C-PRO GIGA RACK APPLICATION MANUAL
Page
56
HC01
C1 comp. DO
position
Sets the position of the
digital output for
compressor 1
Or compressor inverter
consent position
1
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC11
C1 increment 1
DO position
Sets the position of the
increment 1 digital output
for compressor 1
2
0
13 (26)
CO-Hw
Default = 0
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC21
C1 increment 2
DO position
Sets the position of the
increment 2 digital output
for compressor 1
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC31
C1 increment 3
DO position
Sets the position of the
increment 3 digital output
for compressor 1
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC02
Compressor C2
DO position
Sets the position of the
digital output for
compressor 2
Or compressor inverter
consent position
3
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC12
C2 increment 1
DO position
Sets the position of the
increment 1 digital output
for compressor 2
4
0
13 (26)
CO-Hw
Default = 0
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC22
C2 increment 2
DO position
Sets the position of the
increment 2 digital output
for compressor 2
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC32
C2 increment 3
DO position
Sets the position of the
increment 3 digital output
for compressor 2
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC03
Compressor C3
DO position
Sets the position of the
digital output for
compressor 3
Or compressor inverter
consent position
5
0
13 (26)
CO-Hw
Default = 4
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC13
C3 increment 1
DO position
Sets the position of the
increment 1 digital output
for compressor 3
6
0
13 (26)
CO-Hw
Default = 0
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC23
C3 increment 2
DO position
Sets the position of the
increment 2 digital output
for compressor 3
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
HC33
C3 increment 3
DO position
Sets the position of the
increment 3 digital output
for compressor 3
0
0
13 (26)
CO-Hw
Max = 8(16)
on C-PRO
MEGA RACK;
Visibility
*¹
Содержание C-PRO GIGA
Страница 6: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 6 C PRO MEGA ...
Страница 7: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 7 C PRO GIGA ...
Страница 14: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 14 2 5 2 C PRO GIGA RACK electrical connections ...
Страница 22: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 22 2 7 2 C PRO EXP GIGA electrical connections ...
Страница 26: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 26 3 COMPONENT NETWORK AND ACCESSORIES 3 1 Example ...
Страница 50: ...C PRO MEGA RACK C PRO GIGA RACK APPLICATION MANUAL Page 50 compensation line neutral zone 0 NO 1 YES ...