background image

10. CLEANING AND ROUTINE MAINTENANCE 

 

The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation. 

The Buyer must carry out regular cleaning of the stove following the instructions contained in this Instruction Manual, and in particular must carry out daily cleaning 

before each ignition or refilling of pellets, the ash drawer, the fire pit and the combustion chamber. 

Failure to clean and/or routinely maintain the stove can cause: malfunctions, obstruction of the burn pot and pipes, poor or slow combustion, or overheating of the 

stove and fire in the hopper. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused 

by the failure/incorrect cleaning and routine maintenance of the stove. 

 

Perform daily cleaning in a completely cold stove as follows: 

 

Vacuum the base of the fire pit inside the combustion chamber 

 

Perform weekly cleaning in a completely cold stove as follows: 

 

Vacuum the combustion chamber, ensuring that there are no burning embers remaining. If embers 

are still burning, the vacuum cleaner will catch fire; 

 

Remove the ash that collects inside the firebox and on the door. 

 

Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the operation 

is performed with the stove hot there is a risk of the glass exploding. 

 

Empty the ash drawer, by vacuuming it or throwing the ash out with the rubbish. 

 

Vacuum the ash drawer compartment and the adjacent inspection window. 

 

Perform monthly cleaning in a completely cold stove as follows: 

 

Vacuum the T lid of the fume connection. Open the side inspection window and remove the T lid. 

 

Caution: Only use a dry cloth to clean the stove. Do not use abrasive material or products that could corrode or bleach surfaces. At the end of the season, with the 

last ignition, the pellet remaining in the auger must be consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue 

created by moisture. 

 

 

11. EXTRAORDINARY MAINTENANCE  

 

The Buyer must have the flue and flue pipe cleaned annually, before winter, by qualified technical personnel and retaining the documentation to be shown in the 

event of activation of the warranty. 

Before performing maintenance it is recommended to turn the stove off using the power button, and remove the plug. 

Cleaning must also be carried out before resuming use of the stove, as during the summer there may have been impediments to the regular flow of exhaust gases 

(e.g. nesting, fouling or obstruction). 

The lack of extraordinary maintenance can cause: depression with poor draught and a slow flame, clogging of the burn pot and pipes, overheating of the stove and 

fire in the smoke pipe. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the 

failure/incorrect extraordinary maintenance of the stove. 

 

It is not uncommon, at the first cold spell and with wind for fires to ignite in the chimney due to the residue build up; some advice in the unfortunate event of this 

happening is: 

 

Block air supply to the pipe immediately; 

 

Use large handfuls of sand or salt, not water, to extinguish the fire; 

 

Move objects and furniture away from the hot chimney. 

 

Caution: Only use a dry cloth for cleaning the outside of the stove. At the end of the season, with the last ignition, the pellet remaining in the auger must be 

consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue created by moisture. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Содержание SB 80

Страница 1: ...INSTRUCTION MANUAL PELLET STORAGE WATER HEATER PELLET THERMO STOVE Models SB 80 TEK 80 EN...

Страница 2: ...o facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button D...

Страница 3: ...INSTALLATION WARNINGS p 9 06 01 CONNECTION SYSTEM SCHEMATICS p 11 07 INSTALLATION p 12 07 01 HYDRAULIC CONNECTION p 13 07 02 ELECTRICAL CONNECTION p 15 08 ELECTRONICS WITH N 100 3 BUTTON LED DISPLAY p...

Страница 4: ...s type Y the power supply cable may only be replaced by a qualified technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance servi...

Страница 5: ...appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properly i...

Страница 6: ...ket Temperatura uscita fumi C 230 136 Flue gas mass flow Flusso massico dei fumi g s 5 7 3 2 Efficiency Rendimento 90 0 93 5 Total heat output Potenza termica Kw 10 2 5 0 Water heat output Potenza ter...

Страница 7: ...mbly of the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained...

Страница 8: ...ould the existing flue opening not be perfectly perpendicular to the firebox fume outlet use an elbow to connect them The angle with respect to the vertical must never exceed 45 see figure to the side...

Страница 9: ...o an excess of oxygen wears the combustion chamber prematurely A poor draught however slows combustion resulting in a decrease in the stove temperature fume egress inside rooms a loss of stove efficie...

Страница 10: ...ges storage rooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed either internally or externally and must be protected by a grille wire me...

Страница 11: ...RECT INSTALLATION Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall Outdoor air intake with non resealable grid Outd...

Страница 12: ...06 1 CONNECTION SYSTEM SCHEMATICS STORAGE WATER HEATER MODE THERMO STOVE MODE 11...

Страница 13: ...itable guards provided that they do not reduce the minimum cross section When in operation the pellet stove may cause a negative pressure in the room where it is installed No other naked flame applian...

Страница 14: ...40 85 0 03590 90 0 03960 100 0 04340 110 0 05150 Safety hydraulic circuit according to EN 1487 2014 or equivalent in force STORAGE HEATER INSTALLATION MODE ONLY Safety units are devices used in sanita...

Страница 15: ...talled The manufacturer assume no liability for damage to property or injury to persons following failure to install the safety devices correctly THERMO STOVE MODE INSTALLATION Remove the 2 covers for...

Страница 16: ...er on the rear of the item EXTERNAL THERMOSTAT If the item is chosen as a thermo stove an external thermostat may still be installed This operation may only be performed by authorised personnel Use a...

Страница 17: ...can be enabled or disabled Moreover if the time is set to OFF the clock ignores the corresponding control Caution set carefully to prevent overlapping of different activation times of different progra...

Страница 18: ...the exhaust blower switch on Any problem detected during the switching on phase is indicated on the display and the stove goes into alarm status Pellet loading After approx 1 minute the pellet loading...

Страница 19: ...ire alarm phase Should the alarm not be cleared the stove will in any case be switched off and the alarm message will remain on the display AL1 BLAC OUT Power outage alarm Power outage may occur with...

Страница 20: ...displayed and the system is shut down Unscrew the black cap near the pellet hopper cover and press the button to reset the contact SERVICE MESSAGE The stove will display the message SERVICE or SER du...

Страница 21: ...lid Caution Only use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining...

Страница 22: ...MODE BURN POT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5 SECONDS IRREGULAR SLOW...

Страница 23: ...ED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE REAR RESTART THE STOVE...

Страница 24: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Страница 25: ...needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER _______________________________...

Страница 26: ...istics of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be hi...

Страница 27: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Страница 28: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Отзывы: