These devices provide Class 10 motor overload protection. The maximum internal overload
protection level (current limit) is 200% for 5 seconds.
An external motor overload protective device must be provided by the installer where the motor
has a full-load ampere rating of less than 40% of the drive output rating. Refer to Chapter 4:
“Operating Modes” - Motor Overload Protection for user current limit adjustment information..
Internal motor overload is also provided for use with an external thermal device located within
the winding of the motor. This protection cannot be evaluated by Underwriters Laboratories Inc.
and hence it is the responsibility of the Installer and/or local Inspector to determine whether the
overload protection is in compliance with the latest edition of the National Electrical Code,
NEC/NFPA-70.
6KRUW
#
&LUFXLW
#
5DWLQJ
All models of this Servo Drive are suitable for use on a circuit capable of delivering not more
than 5,000 RMS Symmetrical Amperes, 480V maximum.
6ROLG
0
6WDWH
#
6KRUW
0
&LUFXLW
#
3URWHFWLRQ
These devices are provided with Solid-State Short-Circuit (output) Protection. Branch circuit
protection requirements must be in accordance with the latest edition of the National Electrical
Code NEC/NFPA-70.
5HFRPPHQGHG
#
%UDQFK
#
&LUFXLW
#
3URWHFWLRQ
It is recommended that UL Listed (JDDZ) non-renewable cartridge fuses, Class K5 or H; or UL
Listed (JDRX) renewable cartridge fuses, Class H, are installed upstream of the Servo Drive.
Refer to Chapter 11: “Technical Specifications” - Fuse Rating and Recommended Wire Sizes.
0RWRU
#
%DVH
#
)UHTXHQF\
The motor base frequency rating is 500Hz maximum.
)LHOG
#
:LULQJ
#
7HPSHUDWXUH
#
5DWLQJ
Use 60°C Copper conductors only.
)LHOG
#
:LULQJ
#
7HUPLQDO
#
0DUNLQJV
For correct field wiring connections that are to be made to each terminal refer to Chapter 3:
“Installing the Servo Drive” - X1 - Motor and Power Wiring Connections, and X10 - Control
Wiring Connections.
3RZHU
#
:LULQJ
#
7HUPLQDOV
Refer to Chapter 11: “Technical Specifications” - Fuse Rating and Recommended Wire Sizes,
and Terminal Block Wire Sizes.
)LHOG
#
*URXQGLQJ
#
7HUPLQDOV
The field grounding terminals are identified with the International Grounding Symbol
(IEC Publication 417, Symbol 5019).
Содержание 631
Страница 42: ...809 QLWLDO 6HW0XS 964 LJLWDO 6HUYR ULYH ...
Страница 50: ...90 3URJUDPPLQJ RXU SSOLFDWLRQ 964 LJLWDO 6HUYR ULYH ...
Страница 56: ... 09 LDJQRVWLFV DQG DXOW LQGLQJ 964 LJLWDO 6HUYR ULYH ...
Страница 58: ... 05 5RXWLQH 0DLQWHQDQFH DQG 5HSDLU 964 LJLWDO 6HUYR ULYH ...
Страница 64: ...4307 5HIHUHQFH 7DEOHV 964 LJLWDO 6HUYR ULYH ...
Страница 86: ...45049 HUWLILFDWLRQ IRU WKH 6HUYR ULYH 964 LJLWDO 6HUYR ULYH ...
Страница 92: ...4705 XQFWLRQDO ORFN LDJUDP 964 LJLWDO 6HUYR ULYH ...
Страница 94: ......