40
EK-MFR/2
25/02/2016
Arch.5105 601-000147/MN Rev. Y
APPENDIX
A
EK-MFR/2
ELECTRICAL INTERFACE
The following table shows the electrical connections of the EK-MFR/2. Every slot is electrically
interfaced with the EK-MFR/2 signal present in the table below. The matrix configuration
software allows to set the the high speed data signals (A column), so it is possible to obtain the
transit of a signal from a board to another one.
C
B
A
1
GND EARTH
GND EARTH
GND EARTH
2
GND EARTH
Coaxial connection
GND EARTH
3
GND EARTH
GND EARTH
GND EARTH
4
GND EARTH
GND EARTH
GND EARTH
5
GND EARTH
Coaxial connection
GND EARTH
6
GND EARTH
GND EARTH
GND EARTH
7
GND EARTH
GND EARTH
GND EARTH
8
-5V
-5V
-5V
9
+12V
+12V
+12V
10
GND EARTH
GND EARTH
GND EARTH
11
Common Audio (out)
GND EARTH
Common Video pal (out)
12
GND EARTH
GND EARTH
GND EARTH
13
+5V
+5V
+5V
14
NOT CONNECTED
NOT CONNECTED
NOT CONNECTED
15
QSPI_BOARD_EN (in)
QSPI_DIN (in)
HIGH_SPEED_DATA0
16
QSPI_DOUT (out)
QSPI_CLK (in)
HIGH_SPEED_DATA1
17
IRQ_REQ (out)
RESET
HIGH_SPEED_DATA2
18
NOT CONNECTED
HIGH_SPEED_WE
HIGH_SPEED_DATA3
19
10 MHz REF
HIGH_SPEED_OE
HIGH_SPEED_DATA4
20
+3V3
GND EARTH
HIGH_SPEED_DATA5
21
NOT CONNECTED
NOT CONNECTED
HIGH_SPEED_DATA6
22
NOT CONNECTED
NOT CONNECTED
HIGH_SPEED_DATA7
23
NOT CONNECTED
NOT CONNECTED
NOT CONNECTED
24
+2V5
+2V5
+2V5
25
NOT CONNECTED
NOT CONNECTED
NOT CONNECTED
26
GND EARTH
NOT CONNECTED
HIGH_SPEED_CLK
27
GND EARTH
GND EARTH
GND EARTH
28
GND EARTH
Coaxial connection
GND EARTH
29
GND EARTH
GND EARTH
GND EARTH
30
GND EARTH
GND EARTH
GND EARTH
31
GND EARTH
Coaxial connection
GND EARTH
32
GND EARTH
GND EARTH
GND EARTH
The signal direction, when is indicated (for example QSPI_DIN (in)), is related to the board inserted
in the EK-MFR/2 slot.
Содержание EK-MFR/2
Страница 1: ...1 601 000147 Rev Y Arch 5105 25 02 2016 User Manual System ALL4DIGIT EK MFR 2 ...
Страница 9: ...9 601 000147 Rev Y Arch 5105 25 02 2016 1 1 EK MFR 2 BLOCK SCHEME ...
Страница 18: ...18 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Tabella 5 1 Indoor version Set up Table ...
Страница 26: ...26 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Power Loop Configuration With EK AMH 6EK PWS X EK PSI ...
Страница 66: ...66 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y ...