24
EK-MFR/2
25/02/2016
Arch.5105 601-000147/MN Rev. Y
We suppose to have loaded the EK-MFR/2 with the boards represented in the following figure
Slot 0: Empty
Slot 1: Empty
Slot 2: Empty
Slot 3: EK-CDP/1 Rev 4.0 (coaxial adapter) connected to EK-UCT/10 (ODU) with a 100
meters cable.
Slot 4: EK-UNM/2 (modem)
Slot 5: Empty
We analyze the setting of every single menu of the Power Loops supposing of working with the
QPSK modulations to obtain a back-off of 4 db relating the saturate power (0 db) of the transmitter
SHF connected to EK-MFR/2 by the EK-CDP/1 board. In this case, with reference to the table 5.2,
the following values have to be set:
EK-MFR/2
>>Loop
>>>
Enable 1
= yes
>>>
Source 1
= slot3
>>>
Target 1
= slot4
>>>
P Goal 1
= -4db
EK-CDP/1
>>ODU Tx Set
>>>
Enable Tx
= yes
>>>
Cable Length
= 100
EK-UNM/2
>>
Port Sel
>>>
IF out
= Mod
Now the EK-MFR/2 keeps the output power of the transmitter (EK-CDP/1) constant in according to
the power of the modulator (EK-UNM/2).