30
EK-MFR/2
25/02/2016
Arch.5105 601-000147/MN Rev. Y
>>Volt in 0:
Allows to read a DC voltage (0÷12 VDC) eventually present on the
expansion connector.
>> Volt in 1:
Allows to read a DC voltage (0÷12 VDC) eventually present on the
expansion connector.
>> Volt out 0:
Allows to set a DC voltage (0÷12 VDC, 10 mA max) at the output of
the expansion connector.
>>Volt out 1:
Allows to set a DC voltage (0÷12 VDC, 10 mA max) at the output of
the expansion connector.
>>Board Temp:
Allows to read the EK-MFR/2 temperature.
>>12V rail:
Allows to monitory the DC voltage (12VDC) generated from the EK-
PWS/X board and supplied to all EK-MFR/2 slots.
Not valid for EK-PWS/A, EK-PWS/C and EK-PWS/D.
>>3.3V rail:
Allows to monitory the DC voltage (3.3VDC) generated from the EK-
PWS/X board, used by the processor and supplied to all EK-MFR/2
slots.
>>Dc rail in
Allows to monitory the eventual external DC voltage that is present on
the auxiliary connector of the EK-PWS/X board
Not valid for EK-PWS/A, EK-PWS/C and EK-PWS/D
>>Pws Upper Status
Indicates the voltage generated by one of the EK-PWS/A,EK-PWS/C,
EK-PWS/D modules located in the Upper position (before of the O-
ring diode).
Not valid for EK-PWS/x.
>>Pws Lower Status
Indicates the voltage generated by one of the EK-PWS/A,EK-PWS/C,
EK-PWS/D modules located in the Lower position (before of the O-
ring diode).
Not valid for EK-PWS/x.
>>Time to exit:
Allows to set the time when the display is on, afterward the display will
go in stand-by modality, in order to limit the consumption of the entire
machine. It is possible to set the time to exit parameter between
2,10,20, 30 or 360 minute.
>>SCI 2:
Allows to switch on and off the secondary serial interface.
>>Ext Power
Allows to read the value of the power of the external analog Eurotek
unit connected to the EK-MFR/2 by the expansion connector.
Содержание EK-MFR/2
Страница 1: ...1 601 000147 Rev Y Arch 5105 25 02 2016 User Manual System ALL4DIGIT EK MFR 2 ...
Страница 9: ...9 601 000147 Rev Y Arch 5105 25 02 2016 1 1 EK MFR 2 BLOCK SCHEME ...
Страница 18: ...18 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Tabella 5 1 Indoor version Set up Table ...
Страница 26: ...26 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y Power Loop Configuration With EK AMH 6EK PWS X EK PSI ...
Страница 66: ...66 EK MFR 2 25 02 2016 Arch 5105 601 000147 MN Rev Y ...