Installation Manual Dust Free Industrial 8500
7
8.4 Remote Touch Control DFI
A.
Dipswitch settings (SW4)
ID
Default Description
Note
JP1
0
Future use
JP2
0
Fan operation
mode
Not applicable in this mode.
JP3
0
Auto Start
JP3 = 1; DFI starts automatic after power loss
(NON CE!).
JP4
0
Remote
control
JP4 = 0
JP5
0
Future use
JP6
0
Future use
JP7
0
Actuator
JP7 = 0; Actuator disabled.
JP7 = 1; Actuator enabled.
JP8
0
Factory erase JP8 = 1; Factory reset during power up and
pressure sensor calibration. Switch to 0 when
completed.
JP9
0
Filter setup
JP9 = 0; 1 filter installed.
JP9 = 1; 2 filters installed.
JP10
0
Future use
B.
RS-485 address (SW1 & SW2)
ID
Default RC-MSA Master setting
SW1 = X
SW2 = Y
YX = 00 Unit 1 = 01
Unit 2 = 02
Unit 3 = 03
Etc.
C.
Fan speed (SW6)
ID
Description
SW6 = 0
Touch control DFI
SW6 = 1
No valid selection
SW6 = 2
No valid selection
SW6 = 3
No valid selection
SW6 = 4
No valid selection
SW6 = 5
No valid selection
SW6 = 6
No valid selection
SW6 = 7
No valid selection
SW6 = 8
No valid selection
SW6 = 9
No valid selection
These settings for use with a touch control DFI are valid for both wired
systems as for wireless systems via IQRF.
9
TEST RUN
Before powering the DFI perform another safety check:
•
Make sure the DFI is mounted to a suitable carrier.
•
Make sure the DFI is horizontal and secure.
•
Make sure all connections do comply with local/national legislation
and European norms.
Test run
When mechanical and electrical safety is confirmed, let the DFI run for at
least 20 min.
IMPORTANT
Before first use the DFI need to be calibrated.
IMPORTANT
The DFI need to be installed at it’s final location.
Calibration
Press and hold down the run button and switch on the mainswitch. The
indicator starts to flash green/purple. After some time the indicator will turn
white and then the DFI is ready for use.
Settings
Consult the manual of the DFI for settings to create the required
functionality.