Euromag EUROSONIC 2000 HH Скачать руководство пользователя страница 76

76 | EUROMAG 

ft/s

4,914.7

4,593

5,023

3,530.2

2,067

(-164°F)

4,406.2

(68°F)

4,368.4

4,376.6

(68°F)

2,883.9

10,820.2

(842°F)

 

m/s

1,498

1,400

1,531

1,076

630

(-109ºC)

1,343
(20ºC)

1,331.5

1,334
(20ºC)

879

3,298

(450ºC)

Substance

Water,distilled(49,50)
Water,sea
WoodAlcihol(40,41)

Xenon(45)

m-Xylene(46)

o-Xylene(29,46

P-xylene(46)

Xylenehexafluoride

Zinc(7)

1,1,1-Trifluoro-2-Chloro-
2-Bromo-Ethane
1,2,2-Trifluorotrichloro-
ethane(Freon113)

Chemical

Formula

H

2

O

D

2

O

CH

4

O

Xe

C

8

H

10

C

8

H

10

C

8

H

10

C

8

H

4

F

6

Zn

All data given at 25ºC (77ºF) unless otherwise noted.

Sound Speed

Kinematic Viscosity x10

-6

 

ft

2

/s

10.76

10.76

7.478

8.059

(59°F)

9.716

(68°F)

7.123

6.595

 

m

2

/s

0.695

1.00

0.695

0.749
(15ºC)
0.903
(20ºC)
0.662

0.613

v/ºC

m/s/ºC

-2.4

-2.4

2.92

4.1

Specific

Gravity

0.996

1.025

0.791
(20ºC)

0.868
(15ºC)
0.897
(20ºC)

1.37

It comes from the previous page

EUROSONIC 2000 HH 

Содержание EUROSONIC 2000 HH

Страница 1: ...Hand Held Ultrasonic Flow Meter EUROSONIC 2000 HH User Manual READ AND KEEP THESE INSTRUCTIONS TD 204 0 ENG...

Страница 2: ...EUROSONIC 2000 HH...

Страница 3: ...r on 2 3 Keypad 2 4 Menu windows 2 5 Menu window list 2 6 Steps to configure parameters 2 7 Transducer mounting allocation 2 8 Transducer installation 2 8 1 Transducer Spacing 2 8 2 V Method Installat...

Страница 4: ...ow to use the inbuilt data logger 3 15 How to use the frequency output 3 16 How to use the totalizer pulse output 3 17 How to produce an alarm signal 3 18 How to use the built in buzzer 3 19 How to us...

Страница 5: ...charts for Cast Iron Pipe 8 2 5 Standard Pipe size charts for Ductile Iron Pipe 8 3 Sound speed tables 8 3 1 Sound Speed data of solids 8 3 2 Sound Speed in Water 8 3 3 Sound Speed in Liquids List of...

Страница 6: ...6 EUROMAG EUROSONIC 2000 HH...

Страница 7: ...ontamination The hand held flow meter utilizes our proprietary technologies such as advanced signal processing low voltage transmitting small signal receiving with self adapting etc It also incorporat...

Страница 8: ...he pipe and the sound crosses the pipe once The selection of the mounting methods depends on pipe and liquid characteristics The hand held flow meter operates by alternately transmitting and receiving...

Страница 9: ...8 15 100mm M1 Type 2 28 40 700mm L1 Type 11 240 300 6000mm Cable 5 metre X 2 Converter Terminal and AC adapter Cable Rs232 Interface 5m 1m Red Terminal Upstream Transducer Socket Pins for battery rech...

Страница 10: ...that can retain the data for over 100 years even when the power is lost or turned off Password protection is provided to avoid inadvertent configuration changes or totalizer resets A time keeper is i...

Страница 11: ...iquid Barrel Imperial Liquid Barrel Million USA Gallons User configurable 7 digit totals for net positive and negative flow Virtually all liquids Setup lockout Access code needed for unlocking 4x16 ch...

Страница 12: ...12 EUROMAG EUROSONIC 2000 HH...

Страница 13: ...attery its voltage drops below 3V The approximate remaining working time is indicated in this window as well Notice that the battery remaining working time is estimated based on the current battery vo...

Страница 14: ...orks as key when entering numbers Key is the going DOWN key when the user wants to go to the lower menu window It also works as the key when entering numbers Key is the backspace key when the user wan...

Страница 15: ...the cursor on the line that displays 1 Stainless Steel or press the key directly At the end press again to make the selection Generally the key must be pressed to get into the option selection mode fo...

Страница 16: ...sure these two parameters 3 Pipe materials For non standard pipe material the sound speed of the material must be entered Please refer to Appendix C for sound speed data 4 For standard pipe materials...

Страница 17: ...ndow is one between M00 to M09 pressing key will lead to window M90 for displaying diagnostic data Press key again to return to the previous window Press the key to go to window M11 When the current w...

Страница 18: ...lug in transducers that are installed permanently on the pipe by drilling holes on the pipe while liquid is running inside PIPE CONFIGURATION AND TRANSDUCER PLACEMENT 2 8 TRANSDUCER INSTALLATION The t...

Страница 19: ...pipe There are three ways to mount the transducers on the pipe by magnetic force by clamp on fixture and by hand If the pipe material is metal the magnetic force will hold the transducer on the pipe...

Страница 20: ...nd the downstream signals the estimated liquid sound speed the transit time ratio and etc As such one can be sure that the flow meter is working properly and the results are reliable and accurate 2 9...

Страница 21: ...ct the measurement Relocate to a more favourable pipe line 2 9 3 TOTAL TRANSIT TIME AND DELTA TIME The total transit time or travelling time and the delta time are displayed on menu window M93 They ar...

Страница 22: ...22 EUROMAG 6 Are there any other details that do not meet the measurement requirements as recommended before EUROSONIC 2000 HH...

Страница 23: ...ll be from the RED transducer to the BLUE transducer if the value is NEGATIVE the direction will be from the BLUE transducer to the RED transducer 3 3 HOW TO CHANGE THE UNIT READINGS Use menu window M...

Страница 24: ...ayed in window M41 is called the zero cut off value When the absolute value of the measured flow rate is less than the zero cut off value the measured flow rate will be replaced with 0 This is to avoi...

Страница 25: ...rate Refer to 3 4 and 3 5 for the setup of the totalizer units and multiplier The totalizer pulse output can only be connected to OCT devices or BUZZER hardware devices For example assume that the POS...

Страница 26: ...ommended 1 Enter flow rate lower limit 300 in M73 for 1 alarm 2 Enter flow rate upper limit 2000 in M74 for 1 alarm 3 Select item 6 Alarm 1 in M77 3 18 HOW TO USE THE BUILT IN BUZZER The built in buzz...

Страница 27: ...arly totalizer 3 26 HOW TO CHECK THE SERIAL NUMBER Every set of the flow meters utilizes a unique ESN to identify the meter The ESN is an 8 digit number that provides the information of version and ma...

Страница 28: ...28 EUROMAG EUROSONIC 2000 HH...

Страница 29: ...king status Window for entering the outer perimeter of the pipe Window for entering the outer diameter of the pipe Valid range 0 to 6000mm Window for entering pipe wall thickness Valid range 0 55mm Wi...

Страница 30: ...splay the transducer mounting spacing or distance Entry to store the pipe parameters into the internal NVRAM non volatile memory Entry to read the previously saved pipe parameters Entry to determine w...

Страница 31: ...ero point Set up a flow bias Generally this value should be 0 Flow rate scale factor The factory default is 1 Keep this value as 1 when no calibration has been made Network address identification numb...

Страница 32: ...set up the maximum flow rate which corresponds to the upper frequency limit of the frequency output LCD display backlight control The entered value indicates how many seconds the backlight will be on...

Страница 33: ...travelling Display the Reynolds number and the pipe factor used by the flow rate measurement program Note the pipe factor is rarely used Not used Not used Command to store the pipe parameters either...

Страница 34: ...34 EUROMAG EUROSONIC 2000 HH...

Страница 35: ...n Causes Problem with the software User entered parameters get lost Problem with the system clock or the crystal oscillator Problem with the system calendar Hardware problems Solutions 1 Reboot the sy...

Страница 36: ...r 1 Temporary problems with RAM RTC 2 Permanent problems with hardware Instrument is in the progress of adjusting the gain for the signal and the number indicates the progressive steps No liquid insid...

Страница 37: ...entered offset value might be wrong Enter 0 offset in window M44 Incorrect transducer installation Re install the transducers carefully The Zero Point is wrong Go to window M42 and redo the Zero Point...

Страница 38: ...38 EUROMAG EUROSONIC 2000 HH...

Страница 39: ...e following table 6 2 1 BASIC COMMANDS 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 REFERENCES Pin Definition 1 Not Used 2 RXD 3 TXD 4 DTS 5 GND 6 DSR 7 5V 8 Not Used 9 Ring input for connecting a modem f 10 C...

Страница 40: ...value of AI4 0 20mA Return temperature pressure value of AI1 Return temperature pressure value of AI2 Return temperature pressure value of AI3 Return temperature pressure value of AI4 Return the elect...

Страница 41: ...s not used 6 stands for key value For instance value 30H means key 0 command M4 is equivalent to press key 4 7 a stands for current value a digit number of 0 20 For instance A02 34 A00 2 8 dddddddt st...

Страница 42: ...er command so that it will make the programming much easier For example assume we want device IDN 4321 to return the flow rate velocity and POS totalizer value simultaneously The combined command woul...

Страница 43: ...RVICE For operational problems please contact the technical support department by telephone fax email or internet In most cases problems could be solved immediately For any hardware failure of the ins...

Страница 44: ...44 EUROMAG EUROSONIC 2000 HH...

Страница 45: ...ABLES 8 2 1 STANDARD PIPE SIZE CHARTS FOR COPPER Classification Copper tube is classified into four different specification types based on wall thickness for a specific outside diameter The tables pro...

Страница 46: ...RONG Based on designated temper at 65 C 1 bar 0 1N mm2 105 N m2 Usage Above ground services including drinking water supply hot and cold water systems sanitation central heating and other general purp...

Страница 47: ...0 6 0 6 0 6 0 7 0 8 0 9 1 0 1 2 1 2 1 5 1 5 LOW COST UTILITY RANGE Based on designated temper at 65 C 1 bar 0 1N mm2 105 N m2 Usage Above ground services including drinking water supply hot and cold...

Страница 48: ...00 4 20 5 40 Max 1 70 2 00 2 80 3 50 4 20 6 10 I D mm 30 45 38 45 44 05 55 15 81 30 104 60 128 40 146 85 185 15 208 50 PN 9 Wall Thickness Min 1 40 1 70 1 90 2 40 3 50 4 50 5 50 6 30 7 10 7 90 Max 1 7...

Страница 49: ...1 0 126 0 065 0 083 0 109 0 147 0 187 0 294 0 065 0 083 0 113 0 154 0 218 0 308 0 065 0 109 0 133 0 179 0 250 0 358 0 065 0 109 0 140 0 191 0 250 0 382 ANSI B 36 19 Stainless Steel Sch Number 10S 40S...

Страница 50: ...120 0 226 0 318 0 636 0 083 0 120 0 237 0 337 0 438 0 531 0 674 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S ANSI B...

Страница 51: ...75 0 906 0 134 0 165 0 250 0 307 0 365 0 500 0 594 0 719 0 844 1 000 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S 5S 10S 40S 80S ANSI B 36 10 Carbon Steel Wall...

Страница 52: ...250 0 312 0 375 0 438 0 500 0 594 0 625 0 750 0 938 1 094 1 250 1 406 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 40S 80S 5S 10S ANSI B 36 10 Carbon Steel Wall Thickn STD XS XXS STD XS XXS ANSI B...

Страница 53: ...549 0 165 0 188 0 250 0 312 0 375 0 438 0 500 0 562 0 750 0 938 1 156 1 375 1 562 1 781 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 5S 10S ANSI B 36 10 Carbon Steel Wall Thickn STD XS STD XS ANSI B...

Страница 54: ...25 1 875 2 215 0 218 0 250 0 375 0 500 0 562 0 688 0 969 1 219 1 531 1 812 2 062 2 344 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 5S 10S 5S 10S ANSI B 36 10 Carbon Steel Wall Thickn STD XS STD STD...

Страница 55: ...625 0 750 0 312 0 375 0 500 0 625 0 688 0 344 0 375 0 500 0 625 0 688 0 312 0 375 0 500 0 625 0 750 0 375 0 500 0 625 0 750 0 375 0 500 ANSI B 36 19 Stainless Steel Sch Number 5S 10S 10S 10S ANSI B 36...

Страница 56: ...ameter 7 38 9 60 11 84 14 08 16 32 18 54 20 78 23 02 27 76 Wall Thickness 0 48 0 52 0 55 0 60 0 68 0 75 0 82 0 89 0 96 1 03 1 16 1 37 1 58 1 78 1 99 2 23 2 38 Wall Thickness 0 69 0 80 0 92 1 04 1 16 1...

Страница 57: ...0 0 25 0 27 0 29 0 31 0 33 0 34 0 35 0 36 0 38 Class 56 0 40 0 41 0 43 0 45 0 49 0 51 0 52 0 53 0 54 0 56 0 63 0 73 0 83 0 93 1 05 Class 55 0 37 0 38 0 40 0 42 0 47 0 46 0 48 0 49 0 50 0 51 0 53 0 59...

Страница 58: ...eed Shear Wave 25 d Sound Speed Long Wave 25 d m s 3 150 3 230 3 235 3 220 3 120 3 120 3 141 3 070 3 272 3 095 3 100 3 040 2 260 2 235 2 270 2 540 2 060 2 120 1 200 3 020 3 240 3 240 3 000 2 500 2 720...

Страница 59: ...Cement Tar Epoxy Mortar Rubber Sound Speed Shear Wave 25 d Sound Speed Long Wave 25 d m s 3 280 2 380 2 840 1 150 1 070 540 1 060 1 430 ft s 10 761 7 808 9 318 3 772 3 510 1 772 3 477 4 690 mm us 5 61...

Страница 60: ...439 1 1443 2 1447 2 1451 1 1454 9 1458 7 1462 3 1465 8 1469 3 1472 7 1476 0 1479 1 1482 3 1485 3 1488 2 1491 1 1493 9 v 1496 6 1499 2 1501 8 1504 3 1506 7 1509 0 1511 3 1513 5 1515 7 1517 7 1519 7 152...

Страница 61: ...achloride 47 Alcohol Alkazene 13 Alkazene 25 2 Amino ethanol 2 Aminotolidine 46 4 Aminotolidine 46 Chemical Formula CH3CO 2O CH3CO 2O C2H3 N C4H8 O2 C3H6O2 C3H6O C2H3N C6H10O2 C2H2CL2 C2H2Br4 C2H2CL4...

Страница 62: ...Butylalcohol n Butyl bromide 46 Chemical Formula NH3 C5H12O C6H5NO2 C6H5NO2 Ar C6H5N C6H6 C6H6 Br2 C6H5Br C4H9Br C2H5Br CHBr3 C4H10 C4H10O C4H10O C4H9Br All data given at 25 C 77 F unless otherwise n...

Страница 63: ...iFluoromethane 3 Freon 22 Chloroform 47 1 Chloro propane 47 Chlorotrifluoromethane 5 Chemical Formula C4H9CL C4H9CL C22H42O2 C4H10O2 CD CH4O C6H14O3 CO2 CS2 CCL4 CF4 C16H34 C6H5CL C4H9CL CHCLF2 CHCL3...

Страница 64: ...ibromoethene 47 Diburtylphthalate Dichloro t butylalcohol Chemical Formula C9H8O C9H8O C2H7NO C7H8O C7H8O C2H3N C6H12 C6H12O C6H10O C10H20 C10H20 C10H20 C4H6O C10H23N C2H4Br2 C2H2Br2 C8H22O4 C4H8Cl2O...

Страница 65: ...ether Diethylene glycol Diethylene glycol Monoethyl ether Diethylenmide oxide 1 2 bis DiFluoramino butane 43 1 2 bis DiFluoramino 2 methylpropane 43 1 2 bis DiFluoramino propane 43 2 2 bis Difluoromin...

Страница 66: ...odecane 23 1 2Ethanediol Ethanenitrile Ethanoic anhydride 22 Ethanol Ethanol amide Ethoxyethane Chemical Formula C4H10O3 C2H6O2 C8H10 C8H10 C8H10 C6H14 C3H6O C7H16 C8H10O4 CH2l2 C4H8O2 Cl2H26 C2H6O2 C...

Страница 67: ...d amide Freon R12 Chemical Formula C4H8O2 C2H6O C8H10 C2H5Br C2H5l C4H10O C4H10O C2H4Br2 C2H4Cl2 C2H6O2 C10H16O C10H16O F C6H5F C2H4O2 CH3NO CH3NO All data given at 25 C 77 F unless otherwise noted So...

Страница 68: ...47 Hexadecane 23 Hexalin Hexane 16 22 23 Chemical Formula C5H4O2 C5H6O2 C5H4O2 C5H4O2 C5H4O2 C5H6O2 Ga C3H8O3 C3H8O3 C2H6O2 He4 C7H16 C7H16 C5Cl6 C16H34 C6H12O C6H14 All data given at 25 C 77 F unles...

Страница 69: ...cetate 22 lsobutanol lso Butane lsopentane 36 lsopropano 46 Lsopropyl alcohol 46 Chemical Formula C6H14 C6H10O2 C6H14O C6H12 C6H12O C6H12 H2 C7H8O C6H5l C2H5l CH3l C6H12O He4 C4H10O C5H12 C3H8O C3H8O...

Страница 70: ...36 Methy carbinol Methy chloroform 47 Methyl cyanide 3 Methyl cyclohexanol Oil Diesel Chemical Formula C6H10O LiF Hg C6H16O CH4 CH4O C3H6O2 C7H9N C7H9N CH4O C7H8 C5H12 C2H6O C2H3Cl3 C2H3N C7H14O All d...

Страница 71: ...Pentane 36 n pentane 47 Perchlorocyclopentadiene 47 Perchloro ethylene 47 Perfluoro 1 Hepten 47 Perfluoro n Hexane 47 Phene 29 40 41 b Phenyl acrolein Chemical Formula CH10O3 O2 C2HCl5 C2HCl5 C5H12 C5...

Страница 72: ...melicketone Plexiglas Lucite Acrylic PolyterpeneResin Potassium bromide 42 Potassium fluoride 42 Potassium iodide 42 Potassium nitrate 48 Propane 2 13 45 to 130 1 2 3 Propanetriol Chemical Formula C6H...

Страница 73: ...4 Refrigerant12 3 Refrigerant14 14 Refrigerant21 3 Refrigerant22 3 Refrigerant113 3 Refrigerant114 3 Refrigerant115 3 RefrigerantC318 3 Selenium 8 Chemical Formula C3H8O C3H6O C3H6 C5H10O2 C3H8O C3H7...

Страница 74: ...thane 46 Tetrachloro ethene 47 Tetrachlor Methane 33 47 Tetradecane 46 Tetraethylene glycol Tetrafluoro methane 14 Freon14 Tetrahydro 1 4 isoxazine Chemical Formula NaF NaNO3 NaNO2 C2H6O S H2SO4 Te C2...

Страница 75: ...fluoro 2 Chloro 2 Bromo Ethane 1 2 2 Trifluorotrichloro ethane Freon113 d 1 3 3 Trimethylnorcamphor Trinitrotoluene 43 Turpentine Unisis800 Chemical Formula C7H8 C7H9N C7H9N C7H8 CHBr3 C2H3Cl3 C2HCl3...

Страница 76: ...ehexafluoride Zinc 7 1 1 1 Trifluoro 2 Chloro 2 Bromo Ethane 1 2 2 Trifluorotrichloro ethane Freon113 Chemical Formula H2O D2O CH4O Xe C8H10 C8H10 C8H10 C8H4F6 Zn All data given at 25 C 77 F unless ot...

Страница 77: ...EUROMAG 77...

Страница 78: ...78 EUROMAG EUROSONIC 2000 HH...

Страница 79: ...EUROMAG 79...

Страница 80: ...Euromag International SRL Via Torino 3 35035 Mestrino PADOVA ITALY Tel 39 049 9005064 Fax 39 049 9007764 Mail euromag euromag com http www euromag com...

Отзывы: