![Euromag EUROSONIC 2000 HH Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/euromag/eurosonic-2000-hh/eurosonic-2000-hh_user-manual_2439223015.webp)
Pressing
will display the M11 menu
window immediately.
2) Press
or
key. Pressing the
will show
to the user the lower-numbered menu window. For
example, if the current window is on M12, the display
will go to window M11 after the
key is pressed
once.
There are three different types of menu windows:
1) Menu windows for number entering, e.g., M11 for
setting up pipe outer diameter.
2) Menu windows for option selection, e.g., M14 for
the selection of pipe materials.
3) Results display windows, e.g., window M00 for
displaying Velocity, Flow Rate, etc.
For number entering windows, the user can directly
press the digit keys if the user wants to modify the
value. For example, if the current window is on M11,
and the user wants to enter 219.2345 as the pipe
outer diameter, then, the flowing keys should be
pressed:
.
For option selection windows, the user should first
press the
key to get into option selection mode.
Then, use
,
, or digit key to select the right
option. Consequently, press the
to make the
selection.
For example, assume your pipe material is stainless
steel and you are currently on menu window M14
which is for the selection of pipe materials (if you
are on a different window, you need press
first in order to enter into the M14 window.)
You need to press the
key to get into the option
selection mode. Then, either press the
and
keys to make the cursor on the line that displays “1.
Stainless Steel”, or press the
key directly. At the
end, press
again to make the selection.
Generally, the
key must be pressed to get into
the option selection mode for option modifications.
If the “Locked M47 Open’ message is indicated on
the lowest line of the LCD display, it means that the
modification operation is locked out. In such cases,
the user should go to M47 to have the instrument
unlocked before any further modification can be
made.
2.5 MENU WINDOW LIST
M00~M09 windows
are suitable for viewing the
instantaneous flow rate, net totalizer value, positive
totalizer value, negative totalizer value, instantaneous
flow velocity, date time, battery voltage and estimated
working hours for the battery.
M10~M29 windows
have to be used for entering
system parameters, such as pipe outer diameter, pipe
wall thickness, liquid type, transducer type / model,
transducer installation method, etc. Transducer
installation spacing is also displayed on one of the
windows.
M30~M38 windows
allow the user to enter the flow
rate unit and to configure the totalizer. User can use
these windows to select flow rate unit, such as cubic
meter or litre, as well as to turn on / off each totalizer,
or to zero the totalizers.
M40~M49 windows
are for setting response time,
zeroing / calibrating the system and changing
password.
M50~M53 windows
are for setting up the built-in
logger.
M60-M78 windows
are for setting up time-keeper
and displaying software version, system serial
number ESN and alarms.
EUROMAG | 15
MEASUREMENT
Содержание EUROSONIC 2000 HH
Страница 2: ...EUROSONIC 2000 HH...
Страница 6: ...6 EUROMAG EUROSONIC 2000 HH...
Страница 12: ...12 EUROMAG EUROSONIC 2000 HH...
Страница 28: ...28 EUROMAG EUROSONIC 2000 HH...
Страница 34: ...34 EUROMAG EUROSONIC 2000 HH...
Страница 38: ...38 EUROMAG EUROSONIC 2000 HH...
Страница 44: ...44 EUROMAG EUROSONIC 2000 HH...
Страница 77: ...EUROMAG 77...
Страница 78: ...78 EUROMAG EUROSONIC 2000 HH...
Страница 79: ...EUROMAG 79...